GA: Service Gases Flashcards

1
Q

What is the purpose of the 6 N2 storage bottles out by the N2 Skid?

A

They increase the operating time of the ADVs to 16 hours during a Station Blackout.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How is the High Pressure N2 Header pressure maintained?

A

With 2 PCVs

One set at 650 psig with a backup set a 630 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When will the high pressure alarm for the H2 header announce in the Control Room?

A

110 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where do we send H2 in the plant?

A

To the Main Generator

To the VCT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What will trip the N2 Pumps?

A

Cavitation
High Discharge Pressure - 2400#
Low Vapor Temperature - < -20 F
Low Storage Tank Level - 25”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When will the HP N2 Header alarm in the Control Room?

A

On High Pressure at 690 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How long will the HP N2 Storage Cylinders supply the header?

A

They are designed for 7 days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When will the low pressure alarm for the H2 storage banks announce in the Control Room?

A

200 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Can the High Pressure N2 Header supply the Low Pressure N2 Header?

A

Yes, via PV-41

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Do the N2 Pumps supply the Low Pressure N2 Header?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What happens when a N2 pump first starts?

A

It goes through a 15 minute cool down cycle

Liquid N2 flows into the pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When will the HP N2 cylinders alarm on low pressure in the Control Room?

A

750 psig on either bank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How is the H2 header pressure maintained?

A

With 2 PCVs

One set at 105 psig with a backup set a 95 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Describe how the N2 Pumps maintain HP N2 cylinder pressure.

A

Positive displacement pump starts when pressure in the cylinders reaches 1400 psig. The pump will automatically stop when pressure in the tanks reaches 2100 psig.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the power supply to the N2 Pumps?

A

NH

NHN-M30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the power supply to the N2 Containment Isolation Valves?

A

PKA

17
Q

When will the standby N2 pump start?

A

It won’t because it has its local disconnect open

18
Q

What does N2 supply in Containment?

A

The SITs

The RDT

19
Q

How is the Low Pressure N2 Header pressure maintained?

A

With 2 PCVs

One set at 115 psig with a backup set a 110 psig

20
Q

Are the solenoid operated N2 Containment Isolation Valves inside Containment or outside?

A

Outside. The lines have check valves inside Containment

21
Q

What is the administrative limit for H2 Storage Bank pressure?

A

300 psig

22
Q

How are the HP N2 storage cylinders arranged?

A

Total of 8 cylinders
Two banks of 4
Each bank has a PCV
Banks are isolated from one another

23
Q

What will cause the N2 Containment Isolation Valves (GAA-UV-1 and GAA-UV-2) to close automatically?

A

CIAS

24
Q

Describe the High Pressure N2 flowpath.

A

From the N2 Storage Tank, to one of two positive displacement pumps, to the HP vaporizer, to the 8 storage cylinders, to the HP N2 header.