COLSS: Core Operatng Limit Supervisory System Flashcards

1
Q

What is the basis for the COLSS DNBR POL?

A

Assures that the worst AOO wont cause DNBR < 1.34.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the basis for the COLSS LDP POL?

A

13.1 kw/ft assures that 2200F Tclad is not exceeded on a LOCA = assures that fuel wont melt.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is used to calibrate the excore NIs?

A

JSCALOR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is COLSS made up of?

A

CMC and PC: both run identical programs simultaneously and can drive either meter in the Control Room (CMC is normally connected)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How are the inputs divided up between the CMC and the PC?

A

The same inputs go to both computers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What must be done if COLSS is lost?

A

You have to manually surveil DNBR, LHR, Tilt, and ASI.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How does a loss of the PC affect the CMC?

A

The CMC will no longer receive pulse counts = no CEA sequencing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the inputs to JSCALOR?

A

Feed Flow
Feed Temp
Steam Flow
Steam Pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the inputs to NKBDELT?

A
Tc
Th
Ppzr
RCS Mass Flow Rate:
 - RCP RPM
 - RCP D/P
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which inputs in COLSS have redundant sensors that will swap on sensor failure?

A
RCP RPM
RCP D/P
Pressurizer Pressure
Th
Tc
Steam Flow
(basically everything in the can)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How is the Power Limit Margin (Red LED Meter on B05) determined?

A

Displays the most restrictive of the difference between current Selected Power and DNBR POL, LPD POL, and the License Power Limit. At 100% power, the most restrictive is the License Power Limit (~101.5%).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which inputs in COLSS will not swap on sensor failure?

A

Feed Flow
Feed Temp
Steam Pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What COLSS Secondary Power reading gets smoothed to provide JSCALOR?

A

BSCRAW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the equation used to determine Secondary Power?

A

Qsec = m(hstm - hfw) - gains + losses - SGBD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How does JSCALOR react if the Blowdown Constant is increased?

A

JSCALOR reads lower.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the result of NKBDELT calibrated by JSCALOR?

A

JCPCAL

17
Q

How does JCPCAL relate with JSCALOR?

A

JCPCAL is slowly moved toward JSCALOR (1 hr)

18
Q

What is used to calibrate NKBTFST? What results?

A

JSCALOR

NKCBTFST

19
Q

How does NKCBTFST relate with JSCALOR?

A

NKCBTFST is slowly moved toward JSCALOR (1 hr)

20
Q

What does it mean if JSCALOR > NKCBTFST?

A

It means theres a steam leak somewhere

21
Q

What does it mean if JCPCAL and NKCBTFST inputs are bad?

A

It means COLSS is out of service

22
Q

From what is AZTILT calculated?

A

Incores

9 calculations at 5 levels

23
Q

What parts of the AZTILT calculation could put COLSS OOS?

A

< 75% of incore detectors available
< 3 levels available
< 5 calculations

24
Q

What happens if AZTILT > CPC value?

A

Must change the addressable constant in CPC to be more conservative than the COLSS calculated value.

25
Q

Planar Radial Peaking Factors (Fxy) are computed for _____ levels using CEAs and _____.

A

20 levels

CEAs and Tc

26
Q

What is the JSCALOR uncertainty?

A

2%

27
Q

How long does it take to fully reflect a JCSALOR error in Plant Power?

A

about an hour

28
Q

DNBR POL _________ as ASI gets more negative

A

lowers

29
Q

How does Tc deviation from 555F affect POLs?

A

They all decrease (especially LPD)

30
Q

Higher RCP D/P means _______ flow and ________ DNBR POL.

A

lower

lower

31
Q

If COLSS needs to be restarted, how should this be done?

A

On one computer at a time

Allow 10-15 minutes for values to stabilize