SNFO 07: Natural Gas Emergencies Flashcards

1
Q

natural gas is primarily composed of what?

A

methane

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

is natural gas lighter than air?

A

yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

natural gas flashpoint?

A

1200F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

natural gas flammable range?

A

4-14%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

does natural gas dissipate rapidly outside?

A

yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

where does natural gas tend to pocket in buildings?

A

attics, dead spaces

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

should burning natural gas be extinguished?

A

not normally

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

natural gas fires should be controlled how?

A

stoping the flow of gas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

what PPE will be required for responses to gas leaks?

A

full PPE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

what should be established around any suspected gas leak?

A

hot zone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

apparatus placement should be _____ of any potential vapor cloud.

A

upwind

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

if the leak is above ground and the officer feels like the leak can be controlled, what needs to be on the ground?

A

hand line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

NAERG guideline for gas leak distance?

A

330ft in all directions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

secure all _____ gas shutoff valves before attempting to locate the source of the gas and any other shutoff devices.

A

known

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

when a leak is inside the building, where should the gas be shut off?

A

at the meter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

what will a meter possibly show if there is a gas leak?

A

spinning meter

17
Q

what should command do with a meter until repairs are made?

A

red tag out of service

18
Q

if there is any indication of gas accumulating inside the building, what needs to be done?

A

control ignition sources

19
Q

do not shut down power from an outside breaker unless FD has what?

A

has the appropriate gas meter

20
Q

personnel should ensure that blowers are not placed in an _______ enviroment.

A

explosive

21
Q

if the gas company must excavate to fix a leak, what must FD have?

A

1 3/4 on the ground

22
Q

in the event that there is equipment running in the area, what should you do?

A

leave them running

23
Q

units arriving at an explosion must consider what as a cause?

A

natural gas

24
Q

if a gas concentration is encountered inside, adjacent to, or underneath any building, what needs to be secured?

A

all ignition sources

25
Q

the ____ must be eliminated before shutting off any electrical breakers to the individual home.

A

LEL

26
Q

under fire conditions, the breaker should only be shut off when personnel entering the structure could be _________ by not securing the power.

A

endangered

27
Q

who is responsible for locating, and eliminating leaks in the gas system?

A

gas company

28
Q
A