1
Q

What should be assigned to all tools & equipment with an internal combustion engine?

A

A brass tag number.
602.04

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Company markings should be how far from the male hose coupling?

A

15 inches. 602.20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Repair, replacement & adjustment of a major nature or requiring knowledge not normally available is known as?

A

Shop level maintenance. 604.06

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What day of the week shall operators inspect the underside of heavy duty division vehicles?

A

Monday. 604.15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the oil change intervals for diesel & gas vehicles?

A

Diesel = 100 hours
Gas = 4,000 miles.
604.36

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Each Supplementary Apparatus has 3 equipment lists. Where are each of these lists located?

A
  1. At the Station or Bureau where the Apparatus is assigned.
  2. On the Apparatus itself.
  3. An informational copy is kept at Tools & Equipment.

606.08

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Motors on Supplementary Apparatus should be ran for how long? How often?

A

30 minutes, once per week. 606.12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

All equipment (except the log book) should be removed from Supplementary Apparatus if it is expected to be in the shop longer than?

A

24 hours. 606.40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When should SCBA’s be checked & cleaned?

A

Daily & after each use. 608.16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Gasoline tools & Equipment should be ran for 10-20 minutes, until they reach what?

A

Operating temperature. 608.22

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What day are power tools tested?

A

Monday. 610.06

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Boat equipment checks and motor run tests are done on what day? And by who?

A

Wednesday. By the personnel at the assigned station. 612.06

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

During the boat motor run test. The motor should be ran at what speed? For how long?

A

Shift speed. For 5 minutes. 612.20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Mixed fuel for boats should be replaced when it is how old?

A

1 year. 612.32

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How should old boat fuel be disposed of?

A

Placing it in a vehicle that uses gasoline.
612.30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If more than 1/2 of a hose 2 inches or larger needs replaced, what should be done?

A

Get the FAO’s permission to go OOS. 614.12

17
Q

When should folds of hose be changed?

A

Monthly. 614.24

18
Q

How often should rolled hose be unrolled, inverted & re-rolled?

A

Quarterly. 614.26

19
Q

When deciding where to obtain fuel, What are the locations and their level of priorities.

A
  1. Division of fire fuel tanks.
  2. Groves Road
  3. Fleetfield card facilities (gas stations)

604.47

20
Q

If there are no items missing from an apparatus, should there be a notation of this?

A

Yes. An appropriate notation to this effect shall be entered in the company journal.

608.08

21
Q

After an emergency, whenever possible, when shall respiratory protective systems (SCBA) be returned to operation readiness?

A

Before leaving the fire or emergency scene to return to quarters.

606.18

22
Q

How often should a thorough inspection of ropes be performed?

A

A thorough inspection of all ropes shall be performed every 6 months.

608.28

23
Q

Inspection of all ropes shall be completed during what months?

A

May and November

618.04

24
Q

What is the minimum gallon quantity that gas and oil may be mixed?

A

At no time will gas and oil be mixed in less than 6 gallon quantities.

612.30

25
Q

Boat motor grease in the lower, needs to be replaced how often and when?

A

Annually, in April along with the preventative maintenance check.

612.34

26
Q

Who is responsible for testing the high pressure hose?

A

Hose repair technician.
614.90

27
Q

A hydrant shall be pumped dry if used for any purpose between the dates of…

A

October 15 and April 15 of each year.

640.02

28
Q

Whenever possible how many hydrants should be flushed at 1 time to avoid water hammer?

A

Flush 2 or 3 hydrants at one time as to avoid possible water hammer.

640.68

29
Q

What type of hydrant wrench shall be used during hydrant flushing?

A

Double-handled hydrant wrench

640.86

30
Q

During hydrant flushing, the flow of water should not exceed more than how many feet from the hydrant?

A

No more than 2’ to 3’ in front of the hydrant.

640.86

31
Q

If the water being flushed from the hydrant does not clear up after flowing for approximately 10 minutes, what should be done?

A

Allow the hydrant to continue to flow and check the hydrant from time to time.
If the water is clear close it, if not close the hydrant and notify the FAO.

640.90

32
Q

A hydrant should be placed out of service if it fails to flow after being opened how many turns?

A

6 turns.

640.92

33
Q

Can private hydrants be spotchecked by The Columbus division of fire?

A

Hydrants can be spot checked in order to ascertain a degree of compliance with city code.

640.112

34
Q

How are the individual hydrant districts identified? Example: 3-6-5E.

A

Unit, Battalion, Apparatus.
3 unit, Battalion 6, Engine 5.

640.120

35
Q

Ladders will be marked on the outside of both beams approximately _____ inches above the _____ of the ladder.

A

Approximately 18 inches above the butt of the Ladder.

602.26

36
Q

What are the 3 sections of the supplementary apparatus log book?

A

•Log Section
•Hose section
•Maintenance section

606.20

37
Q

Synthetic rubber ribbed hose folds shall be changed how many times a year and what months?

A

•3 times a year
•January, April, August.

614.24