Engine CO OPS ✅ Flashcards

1
Q

The 904K Piercing Nozzle flows what GPM at 100 PSI?

A

175 GPM.

13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The hole for Bresnan Distributors should be placed where?
How big should the hole be?

A

Placed directly above the fire.

Hold should be 12” x 12”.

14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The Elkart Brass R.A.M. XD has a hydraulic stability system that uses reaction force to stabilize it. How many GPM are needed to activate this system?

A

Approximately 350 GPM.

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

After initial knock down, what size hose lines can be extended off of the Mercury Quick Attack Monitor?

A

1-3/4” hose off the end of the 1-1/4” stacked tip.

2-1/2” hose off the outlet base of the unit.

16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Water cans have a discharge time of how many seconds?

A

55 seconds.

17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What type of an extinguisher should be used on sensitive electrical equipment?

A

CO2. It leaves no residue behind.

17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

CFD’s standard water can has a UL rating of 2A. Each A of this rating system is equal to the fire suppression capability of how many gallons of water?

A

1.25 gallons.

17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

With Class B foam, what is the application rate for Hydrocarbons (gasoline & diesel)?

A

3%.

21

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

With Class B Foam, what is the application rate for Polar Solvents (alcohol or acetone)?

A

6%.

21

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the most common cause of Foam Eductor failure?

A

Excessive back pressure.

21

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the correct PSI for the Elkart Inline Eductor & the PRO/Pak?

A

Elkhart Inline Eductor = 200 psi.

PRO/Pak = 100 psi.

Pg 21-22

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the maximum length of 1-3/4 hose that can be used between the Elkart Brass Inline Eductor 125 gpm and the nozzle?

A

200 feet.

23

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

State Farm Blockers / ODOT freeway assistance vehicles can be contacted on what radio channel?

A

D06-FSP, One click past 9 Police Fire.

27

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Smooth Bore Nozzles are designed to operate at what nozzle pressure?

A

50 PSI

32

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the ideal nozzle pattern in a large commercial space?

A

Sweeping motion at the ceiling level.

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the areas where the Split Stretch has the most benefit?

A

Tight urban environments.

Hotel / Motel style residences that have a common access hallway.

62

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

To estimate a stretch, the Length, Width & Set Back of a structure is added together. How many feet are added if there is a one story change in elevation?

A

50 feet

Pg 63

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

If an attack line must be extended, what type of roll offers the fastest deployment because it keeps both couplings in the same place?

A

The double donut roll.

72

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

A single 3”, (vs a 5”) supply line with a shorter lay, can provide up to how many GPM?

A

800 GPM.

82

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Each CFD apparatus mounted pump is rated for how many GPM at draft?

A

1,500 GPM.

90

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

When Pumping in Series, the Supply Pumper should be placed as near the hydrant as possible. This should preferably be within how many feet of the hydrant?

A

25 feet.

91

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the actual discharge capacity of a two-stage pump while in Pressure Mode?

A

70% of the total capacity of the pump.
70% 0f 1,500 GPM is 1,050 GPM.

Pg 99

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Are CFD apparatus pumps kept “Wet” or “Dry”? Regardless of ambient temperature?

A

Wet.

116

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

During prolonged parking during cold weather runs. The pump should be engaged. What 2 valves should be opened?

A

Tank to Pump
Tank Fill

116

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

If the pressure transducers fail on a Pump Boss it will not operate above idle in Pressure Mode. If this happens on scene what is the only option?

A

Use RPM Mode

117

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

What is the starting pressure when supplying the turntable of a Tiller Ladder?

A

150 PSI. Starting point.

119

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

45° of a door CLOSEST to the Engine is?

A

The inside of the door

PG 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

45° of a door FARTHEST away from the engine is?

A

The outside of the door.

PG 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

To help create less of a pinch point, the hose line should be positioned on the side of the door _____ of the fire’s location.

A

Opposite the fire’s location

PG 69

30
Q

There are 2 basic options for extending a hoseline.

A

Extending at the truck
Extending at the nozzle

PG 72

31
Q

Extending an attack line should not be done in a/an _____?

A

Should not be done in a IDLH atmosphere.

PG 73

32
Q

On a garden stretch, the appliance should be placed approximately ____ ft from the attack lines entrance point.

A

Approximately 10 ft

PG 75

33
Q

To combat the weight of the water pulling the hose down during a vertical stretch, what is the “general rule of thumb” for a 2-story stretch and a 3-story stretch?

A

2-story stretch - 50’ of hose on the fire floor landing

3-story stretch - 75’ of hose on the fire floor landing

PG 76

34
Q

The vertical hook stretch method should not be used over how many stories?

A

Should not be used over 3 stories.

PG 77

35
Q

The ELKHART BRASS R.A.M. XD is NOT to exceed how many GPM and/or PSI?

A

Operation is NOT to exceed 500 GPM and/or 150 psi

Pg 15

36
Q

On the MERCURY QUICK ATTACK MONITOR, which stack tip will allow a 1-3/4” hose line to be connected?

A

1-1/4” stacked tip will allow the 1-3/4 hose line to be be connected.

Pg 16

37
Q

Per the UL (Underwriters Laboratories), the “A” in a rating like 2A, each number indicates how many gallons of water?

A

1.25 Gallons.
Examples
2A = 2.5 Gallons
3A = 3.75 Gallons

Pg 17

38
Q

What is the recommended percentage knob setting on the PRO/PAK for ordinary combustible materials using Class A foam?

A

Ordinary combustible materials recommended percentage know setting for class A are 0.1%-1%

Pg 22 and 23

39
Q

CFD carries what 2 series of nozzles?

A

Elkhart Chief and Chief XD series nozzles.

Engines 2019 and newer carry Chief XD

Pg 31

40
Q

The principal that states “when building an attack package, the orifice of the nozzle should ideally not be greater than half the diameter of the hose.”

A

Freeman Principle - Smooth Bore

Pg 31

41
Q

Which CFD nozzles have the “integrated tip”?

A

Elkhart Chief nozzle has the integrated tip.

Pg 35

42
Q

After cleaning a nozzle, what is the recommended lubricant per the operating manual?

A

Dow-Corning #7 lubricant

Pg 36

43
Q

The backup firefighter should check for “LFL”… what does “LFL” stand for?

A

Life - victims
Fire - location/direction
Layout - stairs/rooms

Pg 41

44
Q

A common phrase on the training around the country is “_______”

A

“The fire goes as the first line goes”

Pg 43

45
Q

Initial line selection: What is a 1-3/4” hose line best used for?

A

Anything from a single room and contents fire, up to 3 rooms of fire.

Pg 43

46
Q

Initial line selection: What are two 1 3/4 hose line or one 2” hose line best used for?

A

More than 3 rooms of fire

Pg 43

47
Q

Initial line selection: What is a 2-1/2” hose line best used for?

A

One floor or more of fire

Pg 43

48
Q

Initial line selection: What hose lines are best for commercial structures?

A

2” or 2 1/2” hose line

Pg 43

49
Q

Initial line selection: Consider a Master stream for…

A

Defensive Operations

Pg 43

50
Q

What are the components of the “Exponential Engine Theory”?
- Brian Brush

A

• Enough water to extinguish BTUs
• Every line should be set to fight different fires
• Different “weapons” for different fights
• Rule of Thumb: the next larger line/nozzle size should approximately double the GPM

Pg 43

51
Q

The Andy Frederick’s ADULTS acronym is used to outline 2-1/2” hand line use. What does ADULTS stand for?

A

Advanced fire on arrival
Defensive operations
Unable to determine the extent/size
Large, non-compartmentalized areas
Tons of water
Standpipe System Operations

Pg 43

52
Q

What is the weight of a charged 2” and a charged 2-1/2” hose line per 50’?

A

2” - 68lbs per 50’
2-1/2” - 103 lbs per 50’

Pg 50

53
Q

What is the first and most important consideration when choosing a hand line to combat a fire?
(Size vs. maneuvering)

A

Flow, should be the most important consideration.

Pg 51

54
Q

What hose load used by CFD is the fastest to deploy?

A

Triple Fold

Pg 53

55
Q

What hose load used by CFD is the more versatile around cars and fixed obstacles?

A

Modified Minuteman

Pg 54

56
Q

To estimate the stretch, what 3 to 4 things must be added together?

A

•Length
•Width
•Setback
•Elevation

Pg 63

57
Q

When calculating available hydrant water,what is the remaining supply after a drop 10%, 11-15%, 16-20% and greater than 20% of the static pressure?

A

•0-10% - 3x the amount that caused the drop remaining
•11-15% - 2x the amount remaining
•16-20% - 1x the amount remaining
•>20% - 1/2 the amount remaining

Pg 86

58
Q

What are the driver/pump operators 3 priorities?

A

•Priority one - Get water for crew
•Priority two - Get water for yourself/engine
•Priority three - Get water for everyone else

Pg 94

59
Q

When operating on tank water alone, should the driver/operator charge a backup line?

A

No. They should wait until they have a supply established.

Pg 95

60
Q

Once the attack engine operator opens their supply intake, they should close their TANK TO PUMP to maintain an emergency supply of how much?

A

1/4 tank emergency supply use

Pg 95

61
Q

What are some examples of when the demand for water would exceed the capacity of a two-stage pump in pressure mode?

A

•Multi line operations
•Quick attack operations
•Deck gun operations
•Ladder pipe operations

Pg 100

62
Q

How many INTAKE RELIEF valves does each CFD engine have?

A

3 intake relief valves

Pg 107

63
Q

Newer CFD Sutphen apparatus come with the intake relief valves set to what PSI?

A

Intake Relief valves are set to 180psi

Pg 109

64
Q

What is “Back Flushing”?

A

The act of flowing water in reverse through the pump to clear debris.

Pg111

65
Q

During freezing weather, what drains should remain closed vs open?

A

The master drain should be kept closed, but every other drain should be left open during freezing weather.

Pg 116

66
Q

What are the “FAULT CODES” displayed on the pump boss if the transducers fail?

A

E06 or F06

Pg 117

67
Q

What PSI is the STARTING point at the Platforms pump?

A

80 PSI at the Platforms pump should be the STARTING point.

Pg 121

68
Q

A 3” supply line will require approximately how many gallons per 100’ to fill the hose line?

A

37 Gallons per 100’

Pg 82

69
Q

What is the only operation that can not be done in volume mode?

A

Standpipe Operations

Pg 100

70
Q

What is the max effective range for a water can?

A

44-55 feet

Pg 17