Set 3 Flashcards
- 0PSP03-ZQ-0028 Operator Logs*
- *
If ECW supply temperature is < 75 ˚F and temperature lowers by ≥ 4 ˚F between consecutive log readings, what must the operator do?
Start all ECW pumps
- 0PSP03-ZQ-0028 Operator Logs*
- *
What is the limit for the OT∆T setpoint channel check?
- *10%**
- Instrument Error*
Limit can be exceeded if due to different loop temperatures.
- 0POP01-ZA-0001 Admin Guidelines*
- *
Following an outage, whose permission is needed to waive the initial valve lineup for a system?
Unit’s Operation Manager
One of the following conditions must exist:
- System has remained in service
- No work performed on system and system not modified
- If work performed, then process was controlled by ECO process
Note:
Valves in MAB pit rooms not required to be checked for initial valve lineups
- 0POP01-ZA-0001 Admin Guidelines*
- *
When is the locked component deviation log audited?
Monthly
- Note:*
- Shift Manger/Unit Supervisor responsible for ensuring log updated when locked valve positioned.*
- 0PSP03-ZQ-0028 Operator Logs*
- *
If AFD alarm has been inoperable for > 24 hrs, how often must AFD be logged?
Every 30 mins
- 0POP01-ZQ-0022 Plant OPS Shift Routine*
- *
If multiple channels are not available for a channel check, what must be done?
Compare indicated value with data obtained from previous log
Channel check compares channel’s indication with other indications monitoring the same parameter.
- Has nothing to do with acceptance criteria.
- 0POP01-ZA-0001 Admin Guidelines*
- *
When is Independent Verification NOT required?
Changing position does not render component incapable of performing it’s safety function
- 0POP01-ZQ-0022 Plant OPS Shift Routine*
- *
Who ensures appropriate entries are made in the control room logbook?
Unit Supervisor
- 0POP01-ZA-0001 Admin Guidelines*
- *
While checking the position of a normally locked closed valve, the valve operator cannot be moved due to the locking device. What is the proper method for checking the position of this valve?
Remove the locking device
Check valve in closed direction
- 0POP01-ZA-0001 Admin Guidelines*
- *
When are the emergency operations lockers audited?
Quarterly
- 0POP01-ZQ-0022 Plant OPS Shift Routine*
- *
Who approves the use of temporary logs?
Unit Supervisor
OR
Shift Manager
- 0PSP03-ZQ-0028 Operator Logs*
- *
What leakage rate would force the you to declare the containment sump level / flow monitoring system inoperable?
> 4.7 gpm
- 0POP01-ZA-0001 Admin Guidelines*
- *
When are valves in the AFWST pit required to be checked?
If security barrier is breached
- 0POP01-ZA-0001 Admin Guidelines*
- *
How is a locked throttle valve’s position verified?
Visual Observation
Local Indicators
SM’s permission required to move locked throttle valve.
- 0POP01-ZQ-0022 Plant OPS Shift Routine*
- *
Who reviews the safety function checklist?
Unit Supervisor
On-coming RO completes the safety function checklist