SCCW Flashcards

1
Q

State limitations on placing Aux SCCW heat exchanger in service

A

When Aux HX is in service only 1 SCCW pump can be running

TV-7020 is blocked to 65% open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Consequences of a loss of SCCW

A

If all SCCW flow is lost RX trip

Start removing things cooled by SCCW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State effect of an S signal on SCCW

A

SW-V-4, 5, 74, 76 goes closed

Need to reset S signal to open valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

State effect of a LOP on SCCW

A

SW-V-4 and 5 shut

Need to be back on UAT/RAT to reopen (EPS deactivated)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

State effect of a TA on SCCW

A

SW-V-4, 5, 74, 76 goes closed

TA signal needs to be reset to reopen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State major loads on SCCW

A

H2 coolers
GSC coolers
TLO coolers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

State normal temp band of SCCW

A

77F to 95F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly