MGM Flashcards

1
Q

State advantages of using H2

A
High specific heat capacity
Low Density
Low cost
Non-corrosive
non-conductive
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

State how H2 is cooled in the Generator

A

Fans mounted to the rotor provide motive force for the H2 and passes over the stators and Rotors to the coolers, the coolers are cooled by SCCW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State the basic operation of the core monitor

A

monitors the particulate contamination of the H2 caused by insulation or paint breakdown due to an overheating condition
Placed in service at 1800 RPM due to fans on rotor causing flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

State when bus duct heating auto starts

A
MGB open (all phases)
OR
breaker 11 and 12 open (all phases)
trips on loss of flow or any of the above breaker shuts
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

State when cooling water flow for bus duct cooling starts

A

Initiated at 130F to inservice HX

alarms at 190F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State when loss of Isophase Bus duck cooling causes a turbine setback

A

A loss of both Isophase Bus duct cooling fans
after a 30min delay
turbine setback to 55% at 2%/min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

State relationship between H2 pressure and generator load

A

As load increases H2 pressure must increase to increase heat removal capability

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

State how H2 is changed in the generator

A

H2 is vented out the top and CO2 is admitted through the bottom.
In reverse CO2 gets vented out the bottom and H2 gets admitted through the top

How well did you know this?
1
Not at all
2
3
4
5
Perfectly