Condensate Polishing Flashcards
1
Q
State CPS flow path when in DEMIN mode
A
Flow from all three hotwells goes to CPS-P-401 and then the demins and back to all 3 condensers
2
Q
State CPS flow path when in POLISH mode
A
Flow from the “dirty” condenser goes to CPS-P-401 and then the demins and back to the 2 “clean” hotwells.
The “dirty” hotwell is isolated from the Condensate pumps.
3
Q
State what causes the CPS demin bypass valve to open
A
Cation or Mixed bed high DP - 60#
Total Demin bed high DP - 95#
Cation inlet bed high DP - 125F
4
Q
State what causes CPS-P-401 to trip
A
Undervoltage Overcurrent Low flow of 1000GPM for 30 sec Low hotwell level of -9" high discharge pressure 150# for 3 sec E-stop from PLC or DCS