Condensate Polishing Flashcards

1
Q

State CPS flow path when in DEMIN mode

A

Flow from all three hotwells goes to CPS-P-401 and then the demins and back to all 3 condensers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

State CPS flow path when in POLISH mode

A

Flow from the “dirty” condenser goes to CPS-P-401 and then the demins and back to the 2 “clean” hotwells.
The “dirty” hotwell is isolated from the Condensate pumps.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State what causes the CPS demin bypass valve to open

A

Cation or Mixed bed high DP - 60#
Total Demin bed high DP - 95#
Cation inlet bed high DP - 125F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

State what causes CPS-P-401 to trip

A
Undervoltage
Overcurrent
Low flow of 1000GPM for 30 sec
Low hotwell level of -9"
high discharge pressure 150# for 3 sec
E-stop from PLC or DCS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly