SCBA ADD 2 Flashcards
Do not use the APR’s when
Air hazard not identified Air hazard cannot be filtered Concentrations cannot be measured IDLH Oxygen deficient atmosphere (less than 19.5%) Air is oxygen enriched (above 23%) Air hazard is flammable or explosive Air hazard is CO Not to be used in fire conditions Not to be used in confined space or permit required confined space
Air purifying respirators have certain operational limits and should not be used without
The approval of the IC
The IC should only make the decision to use the APR’s after
Consultation with the Haz Mat Group Supervisor and all the risks have been properly evaluated
In the Battalion vehicle we will have
2 adapters
4 cartridges that will remain sealed in their pouches
An expired MPC Plus Adapter and two MPC Plus canisters can be kept in quarters for training purpose
The expiration date is labeled on
Both the vacuum sealed container and the canister itself
7 year shelf life when stored in its container
The label on the canister must be
Olive green
Only the CBRN CAP 1 canister
Shall be used
Do not carry the adapters or the CBRN CAP 1 canister in
Bunker gear
Remain in their pouches and stored in the infectious control compartment on the apparatus