SB Flashcards
State closing signals for SB IRC valves
Flash tank HI-HI pressure 65#
Flash tank high level 50%
A HELB signal
State Closing signal for SB ORC valves
B HELB
EFW actuation
T Signal
Discuss Where BD flash tank vapor is aligned and how
<10% power to C Condenser
>10% to HTR 23C
pressure is controlled to 55# via PCV-1926-1
Can go to atmosphere via PCV-1926-2
Discuss SB Bottoms coolers
normal outlet temp: 115F
High temp: 200F
on high temp SB-CV-6519
State normal BD flash parameters
Level: 20%
Pressure: 55#
State which valve controls level in the BD flash tank depending on alingment
Ocean: SB-LCV-1909
Condenser: SB-LCV-1909-1
State closing signals for SB-CV-6519
High rad signal from SB rad monitors
High Bottom coolers outlet temp (200F)
State setpoints for the SB Recovery HX
115F: SB-V-398 opens to bypass HX
120F: Alarm at SB panel
Discuss which valves close on a HELB signal
SB IRC valves: Train A SB ORC valves: Train B CS-V-149: IRC Train A CS-V-150: ORC Train B AS-V-175: Train A AS-V-176: Train B
Discuss the operation of the SB Isolation Bypass Switches
Train related switches bypasses signals for ORC SB isolation valves
Train A bypasses MS-V-393 and 394 switches
Train B bypass switches for B EFW pump and MS-V-394 B Train switches
HELB and T Signals are not affected