State Max Delta-T for CW
41F Daily
39F monthly average
State CW SCW alarm setpoints
4” Alarm
18” UA-53 Alarm
60” CW pump trip, after discharge valve is <25% open
List where Bleach can be injected
Intake tunnel ITS DTS CW pump bay SW pump bay
State what CW Lube water supplies
Thrust Bearing oil cooler
Pump Lower Bearing
Pump Packing Gland
State What’s needed to start a CW pump
Discharge valve closed
Lube water flows
All water box vacuum breakers closed
No 86 Device or bus undervoltage
State what will trip a CW pump
CS to stop
60” on screen DP and Discharge valve <25% open
Bus undervoltage( <70% with 1.5sec TD)
86 device
Stat what’s needed to open a CW pump discharge valve
CW pump CS in normal after start
CW pump breaker closed
After 40 second TD valve will open
Or local pushbutton
State what’s needed to close a discharge valve
CW pump CS to pump
High screen DP of 60”
Local push button
State limitation on 3 CW pumps running to 2 condensers
This is limited to 24hours due to high flow in the condenser tubes
State caution on taking CW pump to pull to lock
This will auto stop the CW pump regardless of the discharge valve position.
This prevents back flow through pump from running pumps
State limitation on running 1 CW pump with more than 1 waterbox in service
This is to prevent pump runout