MS/AS Flashcards
Discuss ASDV setpoint and basis
Opening setpoint of 1125# (561F RCS temp)
Full open 1170#, 15 # before safeties
State capacity of ASDV
2.5% design steam flow each
State Main Steam Isolation Signals (MSI)
HI-2 Containment pressure 4.3# 2/3
Steam line pressure low 585# 2/3 w/o P-11
SG Pressure Negative rate high 100# W/50 second time constant 2/3
Discuss A MSI signal
Auto: MSIVs, Bypass valves and upstream Drains close
Manual: MSIVs and Bypass valves close
Discuss B MSI signal
only MSIVs shut
State which ASDVs have backup air
A and B ASDV
When can ASDV control air be used
Control air is only in use when the ASDV is being controlled from its M/A controller
When is N2 used in an ASDV
N2 is used by C/D ASDVs when opening
When in Back up air used in ASDVs
Back up air is used by A/B ASDVs when opening
Discuss ASDVs disabling switches
RSS disabling switches deenergizes train related solenoids (1-4)
Operation is still available through Jog switch in the CR
List opening pressures for the MS Safeties
1185# 1195# 1205# 1215# 1225#
State auto closure setting for MS-V-185 (inlet to Aux Steam reducer)
High aux steam pressure 175#
Low Main Steam Pressure 150#