Temperature and humidity levels need to be monitored and recorded
at least daily
Survey readiness is the responsibility of
every Central Service technician
Product expiration dates are located on this part of each package.
There is no standard place to look for an expiration date.
If an equipment malfunction causes harm to patients, it should be
returned immediately to the Biomedical department
One type of formal monitoring is watching the department’s temperature and humidity levels. (T or F)
True
Occupational Safety and Health Administration is responsible for
ethylene oxide guidelines, worker safety, and the blood-borne pathogen standard.
The ear are made up of three parts
external, eardrum and middle.
The most common reason steam sterilization failure is
a lack of steam contact with the instrument
When using glutaraldehyde technicians should always wear latex gloves for protection
False
Using latex tubing to protect delicate instrumentation is the process of choice for items to be steam sterilized
False
The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is
to keep fluid from entering unit
Healthcare-associated infections are
infections which occur in the course of being treated in a healthcare facility
Items that have been used in patient care should be considered contaminated. (T or F)
True
The term excise means
to cut out
Water must be degassed each time the ultrasonic cleaner’s tank is changed because
excess bubbles from filling reduce the energy of the cavitation process.
Wrapped trays should not be stacked because
it can cause holes in the wrapper of the bottom tray
Woven reusable fabrics are the packaging products of choice for ozone sterilization
False
Instrument lubrication should be performed
Following the manufacturer’s Instruction for Use
Documentation is not required for items that are immediate use steam sterilized. (T or F)
False
Microbes
a. ) can be useful in food products
b. ) are useful to break down sewage
c. ) can produce toxins
d. ) are all of the above
, d.) are all of the above
Each year approximately ________ patients develop a healthcare-associated infection.
700,000
Monitoring records must be
a. ) accurate
b. ) legible
c. ) complete
d. ) all the above
d.) all the above
Always wearing personal protective equipment in the decontamination area is a quality process. (T or F)
True
Case cart systems
a reduce the amount of inventory needed in user departments
Which of the following requires preventive maintenance standards be established for medical equipment?
The Joint Commission
In order to reprocess single-use devices, a hospital must be able to prove the device will act the same as it did when it was first manufactured (T or F)
True
The iris is
the colored portion of the eye
Three of the main phase of a terminal steam sterilizer cycle are
conditioning, exposure and exhaust
The use of heat to kill all microorganisms, except spores, is called
Thermal disinfection
Clean multi-part instruments that have been assembled to test for functionality should
be disassembled and sterilized following manufacturer’s Instructions For Use
The endoscope that would be dispensed for a procedure that required visualization of the lower part of the large intestine would be a
sigmoidoscope
Central Service technicians must wear special attire referred to as ______ to minimize their exposure to bloodborne pathogens and other contaminants
PPE
To help prevent the growth of biofilm, soil on used instruments should be allowed to dry. (T or F)
False
The suffix plasty
is a suffix meaning surgical restoration.
Using untreated water
increases the likelihood of mineral scale deposits
Sterile trays should
a. ) not be touch until they are property cooled
b. ) lifted not dragged off the sterilizer cart.
c. ) checked to be sure the external chemical indicators have turned the appropriate color.
d. ) all the above
d.) all the above
Ethylene oxide is toxic gas
True
Scissors with tungsten carbide cutting edges are usually identified by
Gold handles
The sterilization method of choice for single-use items is immediate use steam sterilization. (T or F)
False
The basic unit of a living organism
cells
Know what it dirty, know what is clean, know what is sterile; keeping the three conditions separate, and remedying contamination immediately are
a principles of asepsis
Documentation of immediate use steam sterilization cycles should include
patient identification and reason for the immediate use steam sterilization cycle
A true Central Service quality program utilizes
all Central Service personnel and a cross section of its customers
Requisition systems are primarily used in large facilities (T or F)
False
When Central Service supports affiliated clinics
planning and communication are is critical
Class III medical devices are identified as high risks (T or F )
False
An organ that filter the blood to remove amino acids and some harmful toxins
Liver
Immediate use steam sterilization is the process to sterilize trays for future use
False
Immediate use steam sterilization is process to sterilize trays for future use (T or F)
False
The U.S. Food and Drug Administration classifies sterilization packaging as a
Class II medical device
Loaner instruments should
be decontaminated before use
Maintaining professional conduct standards and adapting to changing situations are examples of
employability skills
Users are responsible to notify Central Service if they discover instruments or equipment that are in need of repair (T or F)
True
The term ostomy
is a suffix
Instrument lubrication is performed
after cleaning
The bottom shelf of any sterile storage system should be
solid and eight to 10 inches from floor