Progress test Flashcards

1
Q

Validity of license to operate a general clinical laboratory:
A. 1 year
B. 4 years
C. 3 years
D. 10 years

A

1 year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Validity of license to operate a non-hospital based blood service
facilities:
A. 1 year
B. 4 years
C. 3 years
D. 10 years

A

3 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Validity of license to operate a screening drug testing laboratory:
A. 1 year
B. 4 years
C. 3 years
D. 10 years

A

1 year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Validity of license to operate a confirmatory drug testing laboratory:
A. 1 year
B. 4 years
C. 2 years
D. 10 years

A

2 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

_______Failure to secure license to operate clinical lab is punishable by ____year/s of
imprisonment:
A. 1 month to 1
B. 10
C. 2
D. 12-20

A

A. 1 month to 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Failure to secure license to operate blood service facilities is punishable by___ year/s of
imprisonment:
A. 1 month to 1
B. 10
C. 2
D. 12-20

A

1 month to 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Failure to dispose of contaminated blood units within 48 hours is punishable by ___year/s of imprisonment:
A. 1 month to 1
B. 10
C. 2
D. 12-20

A

b. 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

__This is also known as the “National Blood Services Act of 1994”:
A. RA 5527
B. RA 7719
C. RA 7170
D. RA 9165

A

b. RA 7719

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

This is also known as “The Organ Donation Act of 1991”:
A. RA 5527
B. RA 7719
C. RA 7170
D. RA 9165

A

c. RA 7170

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

__This is also known as “The Philippine AIDS Prevention and Control
Act of 1998”:
A. RA 5527
B. RA 8504
C. RA 7170
D. RA 9165

A

RA 8504

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Hi-Accuracy Lab is a freestanding laboratory serving industrial companies that hold annual physical examination to thousands of their employees and officials. The lab tests
include cbc, urinalysis, and fecalysis. Additional tests like fasting blood sugar, total
cholesterol, and quantitative platelet count may also be requested, however, these tests must be sent out to other laboratory since Hi-Accuracy Lab is not offering them.

What is most likely the category of this laboratory, based on services?
A. Primary CL
B. Secondary CL
C. Tertiary CL
D. Limited-Service CL

A

Primary CL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Hi-Accuracy Lab is a freestanding laboratory serving industrial companies that hold annual physical examination to thousands of their employees and officials. The lab tests
include cbc, urinalysis, and fecalysis. Additional tests like fasting blood sugar, total
cholesterol, and quantitative platelet count may also be requested, however, these tests must be sent out to other laboratory since Hi-Accuracy Lab is not offering them.

Which of these lab tests is/are not performed in Hi-Accuracy Lab?
A. Blood chemistry
B. Culture and sensitivity
C. Serology
D. All of the above

A

c. Serology

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Hi-Accuracy Lab is a freestanding laboratory serving industrial companies that hold annual physical examination to thousands of their employees and officials. The lab tests
include cbc, urinalysis, and fecalysis. Additional tests like fasting blood sugar, total
cholesterol, and quantitative platelet count may also be requested, however, these tests must be sent out to other laboratory since Hi-Accuracy Lab is not offering them

Where should Hi-Accuracy lab secure/renew its license to operate?
A. DOH-CHD
B. DOST
C. RITM
D. CLSI

A

A. DOH-CHD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How long is the CL license valid?
A. 1 year
B. 2 years
C. 3 years
D. Lifetime

A

A. 1 year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How often Hi-Accuracy Lab should be inspected by the DOH-BHFS?
A. once a year
B. every 2 years
C. twice a year
D. every 3 years

A

A. Once a year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Mandatory personnel of Clinical laboratory;
A. Medical Technologist
B. Pathologist
C. Laboratory technician
D. A and B only

A

Medtech n Pathologist

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Proficiency testing is conducted by:
A. sending known unknown samples to reference laboratories for analysis
B. sending unknown samples to clinical laboratories enrolled to quality assessment
program
C. running control samples
D. running patient samples on different occasions

A

B. sending unknown samples to clinical laboratories enrolled to quality assessment
program

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The place where the LICENSE TO OPERATE clinical laboratory must
be displayed:
A. the pathologist’s office
B. the med tech’s office
C. the cashier’s office
D. reception area of the lab

A

D. reception area of the lab

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Microbiological tests are performed in what category of CL?
A. Primary
B. Secondary
C. Tertiary and Secondary
D. Tertiary

A

B. Secondary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Which of these laboratories does not require license to operate?
A. Research laboratories
B. Academic laboratories
C. Laboratories in barangay health centers
D. A,B, and C

A

A, B, and C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

A DOH issuance allowing blood bank facilities to perform component processing;
A. AO series 2008-00008-A
B. AO series 2008-00008
C. AO series 2007-00027
D. AO series 2010-00008

A

B. AO series 2008-00008

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

A facility limited to recruitment, screening, and collection of blood only:
A. Blood collection unit
B. Blood station
C. Blood storage facility
D. Blood center

A

A. Blood collection unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

The license to operate and authority to operate a hospital-based blood service
facility is valid until:
A. 1 year
B. 3 years
C. 2 years
D. indefinitely

A

A. 1 year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Confirmatory testing to all blood units that are screened positive
for HIV and other STD’s is done in:
A. RITM
B. East Avenue Medical Center
C. San Lazaro Hospital-SACC
D. NKTI

A

A. RITM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Any person who knowingly and willfully consents to drug pushing, uses his/her influence, power or position in shielding and harboring individuals who violate the provision of RA 9165.Donor A. Legatee B. Coddler C. Testator
B. Coddler
26
As defined by RA 9165, this individual is the one undergoing drug testing: A. Donor B. Spouse C. Legatee D. Testator
B. Spouse
27
Purposes of AIDS Control and Prevention Law, EXCEPT; A. To promote the use of prophylaxis B. To protect civil liberties of persons with HIV C. To promote the human rights of person with HIV D. To promote awareness of the cause and consequences of HIV
B. To protect civil liberties of persons with HIV
28
The mode of finding and counseling of, of the sexual partners of HIV positive person; A. Post-test counseling B. Contact tracing C. HIV monitoring D. All
D. All
29
Prohibited acts in violation of human rights of HIV positive person; A. Pre-employment requirement B. Segregation in school activities C. Restriction of the right to travel D. All
D. All
30
Confirmatory testing for blood specimens that are screened positive for HIV voluntary testing is done in: A. RITM B. East Avenue Medical Center C. San Lazaro Hospital-SACCL D. NKTI
A. RITM
31
The drug test certificate/result is valid for how long? A. 6 months B. 1 year C. 2 years D. lifetime validity
A. 6 months
32
Urine samples that are tested negative for drug metabolites must be kept in the refrigerator before disposal for at least how many days? A. 5 B. 15 C. 10 D. 20
A. 5
33
Mandatory drug testing is applicable to the following; EXCEPT: A. Driver’s license application B. Students C. Candidate of public office D. Police and military
B. Students
34
A registered medtech owns a clinical laboratory, which of the following he/she is NOT allowed to do? A. Supervise the laboratory B. Transact business with the suppliers C. Be one of the staff of the lab. D. All
A. Supervise the laboratory
35
Which of the following is NOT acceptable for medical technologist? A. Prepare reagents for laboratory use B. Own clinical laboratories C. Perform quality control procedures D. Collect CSF and tissues for analysis
C. Perform quality control procedures
36
Approval date of RA 8981 A. December 05, 2000 B. May 15, 1994 C. May 12, 1994 D. May 01, 1994
A. December 05, 2000
37
Disorder having the highest occurrence in newborn Screening A. Cushing syndrome B. Galactosemia C. G6PD Deficiency D. Addison’s syndrome
C. G6PD Deficiency
38
Total hours of duty in Medical Technology Internship A. 1200 hrs B. 1080 hrs C. 1077 hrs D. 1300 hrs
B. 1080 hrs
39
Person who may execute a donation of all or parts of the human body of the deceased A. Deceased spouse B. Either parent C. Brother/Sister of parents D. Children of sound mind
B. Either parent
40
Reference laboratory for newborn screening A. National Institute for Children B. National Institute of Health C. National Institute of Hygiene D. National Institute for Research
B. National Institute of Health
41
The enactment of RA 4688 otherwise known as “Clinical Laboratory Act of 1966” took place on A. June 16, 1966 B. July 18, 1966 C. June 18, 1966 D. February 13, 1966
June 18, 1966
42
Regular inspection of clinical laboratories is done every ________?
o Every 2 years
43
Are MT allowed to supervise CL?
No  MT can own and work in lab but not manage  Pathologists manage the lab
44
Crystal Lab is a tertiary, privately owned laboratory whose main lab is situated in Makati. It has branch labs in:  E. Rodriguez Ave., Quezon City o Tertiary category  Binondo, Manila o Tertiary Category  Taft Ave., Pasay City o Secondary Category **Which of these would require a license to operate? A. Only the main lab in Makati B. Main lab + the 2 tertiary branch lab C. Main lab + secondary CL D. Main labs + all the branch labs
D. Main labs + all the branch labs
45
Validity of license to operate laboratories?
o 1 year only
46
A clinical laboratory installed a dialysis center performing lab tests limited to creatinine and BUN determinations is classified as:
Limited-service CL
47
Most recent implementing rules and regulations for RA 4688
AO #37 series 2021
48
All clinical pathology reports must be kept on file in the laboratory for how long?
At least 1 year
49
Where should a clinical lab secure/renew its license to operate? A. DOH-BHFS B. DOH-CHD C. Either D. Neither
B. DOH-CHD
50
How long is the license of clinical labs performing diagnostic tests valid? A. 1 year B. 2 years C. 3 years D. Lifetime
1 year
51
Mandatory personnel of clinical laboratory: A. Medical Technologist B. Laboratory technician C. Pathologist D. A and C
A and C
52
The application for renewal of license to operate clinical laboratories begin _____ days before expiration day. A. 20 B. 60 C. 30 D. 90
90
53
Based on AO #8 series 2008, centralized processing and centralized testing Is done in blood service facility (BSF) A. BS B. BC C. BCU D. BSF
B. BC
54
License to operate a hospital blood service facility is valid for how long? A. 1 year B. 3 years C. 2 years D. Indefinitely
A. 1 year **Hospitals go through the one-stop shop hospital licensing scheme
55
Who is qualified to supervise a blood service facility? A. Pathologist B. Hematologist C. Physician trained by DOH for 6 months in blood services D. All
D. All
56
The application for renewal of license to operate blood service facilities begins ___ days before expiration day. A. 20 B. 60 C. 30 D. 90
60
57
What is the reference laboratory for transfusion transmissible infections (TTI)? A. Research Institute for Tropical Medicine (RITM) B. East Avenue Medical Center (EAMC) C. San Lazaro Hospital SACCL D. National Kidney and Transplant Institute (NKTI)
A. Research Institute for Tropical Medicine (RITM)
58
An individual who has been screened by history and physical examination, found to be fit to donate blood and included in the list of qualified voluntary donors. Who is ready to donate blood when needed in his or her community? A. Blood donor panel B. Walking blood donor C. Walking blood bank D. All
D. All **Many names for people who could provide immediate blood donation of any blood type that needs a transfusion
59
Failure to secure license to operate blood service facilities is punishable by ___ year/s of imprisonment. A. 1 month to 1 B. 10 C. 2 D. 12-20
D. 12-20 **Owner/supervisor may be prosecuted
60
Failure to dispose of contaminated blood units within 48 hours is punishable by ___ year/s of imprisonment A. 1 month to 1 B. 10 C. 2 D. 12-20
B. 10
61
Which of the following BSF can be reclassified in order to perform additional procedures, such as component preparation? A. BS B. BC C. BCU D. BB
D. BB
62
A blood bank that is reclassified to perform component processing, in addition to its original services, is called: A. BC++ B. BB++ C. BS+ D. BC/BCU
B. BB++
63
Which of the following statement is FALSE? a. All CL shall be headed by a pathologist certified in Clinical Pathology by the Board of Pathology of the Philippine Society of Pathologists b. The head of laboratory shall ensure the optimal overall operations and maintenance of the CL and if applicable. c. The head of the CL shall be a pathologist d. Tertiary CL with anatomic pathologyservice which shall be headed by a pathologist certified Clinical Pathology only
d. Tertiary CL with anatomic pathology service which shall be headed by apathologist certified Clinical Pathology only
64
Certificate of registration for research laboratories is valid for _____ year/s. a. 3 b. 2 c. 1 d. Permanently
a. 3
65
Which of the following statement is FALSE? a. By definition, a working area doesn’t include other parts of the lab like waiting area and comfort room. b. A primary clinical lab must have at least 10 sqm working area. c. The minimum size of clinical laboratories varies, depending on the category based on services. d. A secondary clinical lab must provide at least 25 sqm working area.
d. A secondary clinical lab must provide at least 25 sqm working area.
66
Which of the following lab procedures require that the medtech undergo proficiency training before authorizing him/her to perform such procedure? a. Fecalysis b. HIV testing c. Urinalysis d. CBC
b. HIV testing
67
Most recent implementing rules and regulations for RA 4688: a. AO 2021-00037 b. AO 2008-00008 c. AO 2007-00027 d. AO 2022-00037
a. AO 2021-00037
68
Guidelines in Securing a License to Operate a COVID-19 Testing Laboratory in the Philippines. a. AO 2021-00037 b. AO 2008-00008 c. AO 2007-00027 d. AO 2020-00014
d. AO 2020-00014
69
Validity of license to operate a general clinical laboratory: a. 1 year b. 10 years c. 3 years d. 4 years
a. 1 year
70
The enactment of RA 4688 otherwise known as “Clinical Laboratory Act of 1966” took place on: a. July 18, 1966 b. June 18, 1966 c. June 16, 1966 d. February 13, 1966
b. June 18, 1966
71
Validity of license to operate a non-hospital based blood service facilities: a. 10 years b. 1 year c. 3 years d. 4 years
c. 3 years
72
The place where the LICENSE TO OPERATE clinical laboratory must be displayed: a. The pathologist’s office b. The x-ray unit c. Waiting area of the lab d. The medtech’s office
c. Waiting area of the lab
73
The license to operate and authority to operate a hospital-based blood service facility is valid until: a. 1 year b. Indefinitely c. 2 years d. 3 years
a. 1 year
74
Proficiency testing is conducted by: a. Running control materials b. Running patient samples on different occasions c. Sending known samples to reference laboratories for analysis d. Sending unknown samples to clinical laboratories enrolled to quality assessment program
d. Sending unknown samples to clinical laboratories enrolled to quality assessment program
75
A facility limited to recruitment, screening, and collection of blood only: a. Blood collection unit b. Blood storage facility c. Blood station d. Blood center
a. Blood collection unit
76
This is also known as the “National Blood Services Act of 1994”: a. RA 7170 b. RA 7719 c. RA 5527 d. RA 9165
b. RA 7719
77
The first case of HIV infection in the Philippines was recorded in the year _? a. 1984 b. 1989 c. 1982 d. 1992
a. 1984
78
Ecstacy is otherwise known as _? a.Methylenedioxymethamphetamine b. Methamphetamine HCl c. Lysergic Acid Diethylamide d. Ketamine
a.Methylenedioxymethamphetamine
79
Legal principle that recognizes the capacity of some minors to consent independently to medical procedures a. Gillick principle b. Gillick competence c. All of the choices d. Mature Minor Doctrine
c. All of the choices
80
The sale, distribution, supply or transport of legitimately imported, in-transit, manufactured or procured controlled precursors and essential chemicals, in diluted, mixtures or in concentrated form, to any person or entity engaged in the manufacture of any dangerous drug, and shall include packaging, repackaging, labeling, relabeling or concealment of such transaction through fraud, destruction of documents, fraudulent use of permits, misdeclaration, use of front companies or mail fraud. a. Trading b. Illegal Trafficking c. Deliver d. Chemical Diversion
d. Chemical Diversion
81
How many articles does RA 9165 contain? a. 10 b. 15 c. 13 d. 12
c. 13
82
RA 8504 a. December 20, 2018 b. January 12, 1997 c. December 3, 1992 d. February 13, 1998
d. February 13, 1998
83
How many sections does RA 9165 contains? a. 105 b. 104 c. 102 d. 106
c. 102
84
Which of the following instance does not require drug testing? a. None of the choices b. Appointed government official c. Applicant for firearm license d. Charged by the court with criminal offense of 5 years imprisonment
d. Charged by the court with criminal offense of 5 years imprisonment
85
Organ Donation Act a. RA 8501 b. RA 7170 c. RA 7719 d. RA 10586
b. RA 7170
86
All of the following instance can be punished by 12-20 years of imprisonment except. a. Possession of precursor substances b. Cultivation of marijuana c. Possession of 5 grams of shabu d. Unnecessary prescription of dangerous drugs
b. Cultivation of marijuana
87
IDTOMIS use was implemented on a nationwide coverage on _? a. October 5, 2003 b. April 11, 2006 c. July 11, 2003 d. January 5, 2009
d. January 5, 2009
88
National Blood Services Act a. RA 8504 b. RA 7170 c. RA 7719 d. RA 10586
c. RA 7719
89
Transactions involving the illegal trafficking of dangerous drugs and/or controlled precursors and essential chemicals using electronic devices such as, but not limited to, text messages, e-mail, mobile or landlines, two-way radios, internet, instant messengers and chat rooms or acting as a broker in any of such transactions whether for money or any other consideration in violation of this Act. a. Controlled Delivery b. Chemical Diversion c. Illegal Trafficking d. Trading
d. Trading
90
Which of the following is not a ground for compulsory HIV testing? a. Informed choice is given b. Intimidated c. Lack of consent d. Prerequisite for travel
a. Informed choice is given
91
How many drug testing laboratory can a pathologist supervise? a. 20 b. 13 c. 10 d. 15
c. 10
92
PNAC shall formulate and periodically update the _ year AIDS Medium Term Plan. a. 5 b. 6 c. 10 d. 3
b. 6
93
Which of the following profession does not qualify to be a drug analyst? a. Chemical Engineer b. Pharmacist c. Microbiologist d. Medical Technologist
c. Microbiologist
94
Integrated Drug Test Operations and _ Information System a. Manual b. Health c. Managing d. Management
d. Management
95
Philippine National AIDS Council (PNAC) a. Section 5 b. Section 6 c. Section 7 d. Section 4
d. Section 4
96
RA 9165 Section 3 a. Declaration of Policy b. Title c. Definition of terms d. Maintenance of a Den, Dive or Resort
c. Definition of terms
97
All of the following courses have the same laboratory hours requirement except. a. Health Information System for MLS b. Community and Public Health c. Molecular Biology and Diagnostics d. Inorganic and Organic Chemistry
a. Health Information System for MLS
98
Certificate of accreditation for water testing laboratories shall be renewed _ days before expiry. a. 20 b. 60 c. 30 d. 90
b. 60
99
Odd one out a. Principles of MLS Practice 1 b. Health Information System for MLS c. Human Histology d. Seminar 1
b. Health Information System for MLS
100
Odd one out a. Human Anatomy and Physiology with Pathophysiology b. Biostatistics and Epidemiology c. Analytical Chemistry d. Community and Public Health for MLS
d. Community and Public Health for MLS
101
CHED seed capital a. 500 M b. 5 M c. 50 M d. 3 M
a. 500 M
102
Required number of contact hours in Internship for Hematology Section. a. 220 hours b. 100 hours c. 200 hours d. 300 hours
d. 300 hours
103
Required number of contact hours in Intership for Clinical Chemistry Section. a. 300 hours b. 200 hours c. 100 hours d. 220 hours
a. 300 hours
104
Which of the following offices processes renewal for water testing laboratories? a. PNRI b. HFSRB c. EAMC d. CHD
d. CHD
105
Water testing laboratory that test for aesthetic characteristics. a. Chemical analysis laboratory b. Bacteriological analysis laboratory c. Physical analysis laboratory d. Biological analysis laboratory
c. Physical analysis laboratory
106
Total contact hours for laboratory from First year to Third year MLS Student. a. 1646 hours b. 1782 hours c. 1728 hours d. 1664 hours
c. 1728 hours
107
The intial appointee as the Chairman of CHED shall serve _ years. a. 3 b. 2 c. 4 d. 1
c. 4
108
The Commission on Higher Education is composed of how many full time members? a. 4 b. 6 c. 5 d. 3
c. 5
109
Odd one out a. The Life and Works of Rizal b. Art Appreciation c. Ethics d. Readings in Philippine History
a. The Life and Works of Rizal
110
Clinical Internship courses a. 25 units b. 28 units c. 65 units d. 24 units
b. 28 units
111
Core courses a. 25 units b. 28 units c. 24 units d. 65 units
a. 25 units
112
Water testing report shall be kept for a span of _ years. a. 3 b. 5 c. 1 d. 10
b. 5
113
additional members of the Board of Advisers can be added upon recommendation of CHED. a. 1 b. 3 c. 4 d. 2
d. 2
114
Headship of the water testing laboratory cna be given to the following professionals except. a. Registered Medical Technologist b. Microbiologist c. Registered Pharmacist d. Licensed Sanitary Engineer
b. Microbiologist
115
Department of Education, Culture and _? a. Sports b. Technology c. Society d. Science
a. Sports
116
All of the following courses have the same laboratory hours requirement except. a. Analysis of Urine and Other Body Fluids b. Clinical Bacteriology c. Hematology 1 d. Immunology/Serology
b. Clinical Bacteriology