PRAC CODES Flashcards

1
Q

What is the Occupant load factor for an assembly space with tables and chairs, like a conference room?

A

15 sf per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the Occupant load factor for an assembly space with non-fixed chairs only?

A

7 sf per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the occupant load factor for an assembly space with standing space?

A

5 sf per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the occupant load factor for a business space?

A

150 sf per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the occupant load factor for an exercise space?

A

50 sf per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the occupant load factor for a mercantile space?

A

60 sf per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How many exits per story are required with an occupant load of 1-500?

A

2 exits required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How many exits per story are required with an occupant load of 500-1000?

A

3 exits required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many exits per story are required with an occupant load of >1000?

A

4 exits required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What does the occupant load need to exceed to require 2 exits from a space?

A

49

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the maximum travel distance for a non-sprinklered and sprinklered Assembly, or Mercantile space?

A

200’ non sprinklered
250’ sprinklered

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the maximum travel distance for a non-sprinklered and sprinklered Business space?

A

200’ non-sprinklered
300’ sprinklered

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where are guards required? How high do they need to be?

A

at openings, landings, ramps and balconies that are more than 30” A.F.F.

required to be 42” A.F.F.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Electrical outlets should be how far A.F.F. unless otherwise noted?

A

18”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

All electrical outlets located within ____” of a water source must be GFI

A

36”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What to think about for electrical outlets at residential kitchen?

A
  1. Each appliance needs an outlet (240V outlet for stove/oven, and GFI outlet for dishwasher)
  2. Stove or heating appliance needs 240V outlet
  3. Dishwasher needs GFI outlet
  4. include convenience outlet on either side of sink at 42” AFF
  5. outlets within 36” of water need to be GFI
17
Q

Where to look in the code for required separation of occupancies?

A

Table 508.4

18
Q

Is separation needed for accessory occupancies or incidental use spaces?

A

Only incidental use spaces require separation

exceptions: Group H, dwelling/sleeping unit demising walls