PAES 203:2000 Flashcards
amount of moisture in the grain expressed as percentage of the total weight of the sample, wet basis
moisture content
method of grain moisture determination based on actual extraction of water either by convection heating (oven method) or distillation
primary method
method of grain moisture determination based on some characteristics of the grain sample such as electrical resistance and capacitance which are related to moisture content and must be periodically calibrated against an official primary method
secondary method
accurate balance graduated to permit 0.001g reading and accuracy of + 0.001g
analytical balance
clean, heavy glass with ground-on cover with knob, and should contain standard desiccant
(i.e. silica gel)
desiccator
– laboratory mill, having the following characteristics:
3.3.1 made of material which does not absorb moisture;
3.3.2 easy to clean and having as little dead space as possible;
3.3.3 enabling grinding to be carried out rapidly and uniformly, without appreciable development of heat and as far as possible without contact with the outside air.
grinding mill
drying containers with lid, having a diameter of at least 50 mm. (Aluminum/pyrex glass drying containers with cover, capacity = 30ml with 50 mm diameter.)
moisture dishes
ventilated drying oven with temperature range that can be regulated
Oven
(e.g. capacitance type, resistance type etc.)
secondary moisture meters
(e.g. sack-type spears or triers, shovels etc.)
sampling apparatus
The moisture meter shall be calibrated every ?
6 months
This device consists of a hopper mounted over a cone, which has a number of small collecting bins around its base. In operation, the divider is set on a level surface.
Sample divider
In most cases the size of sample collected is large, making it difficult to manage. A method that may be used to reduce these samples to a manageable level and yet still possess the same characteristic elements present in the whole population is called?
Coning and quartering
Moisture content measurements should be measured when the grain has?
cooled to ambient temperature.