N62 Condenser Air Removal Flashcards
When does condensate begin to inject into the vacuum pumps
and why?
24 inches Hg
Keeps the discharge temp below 350°f
What will close the F003 A/B and why?
Low steam flow condition of less than 7580 Ibm/hr at the second stage SJAE
Prevent exceeding 4% hydrogen
What’s the purpose of condenser air removal?
Achieve and maintain vacuum in the main condenser
Where does the SJAE receive steam from?
Equalizing header
What’s the purpose of the loop seal?
Prevents non-condensibles from leaking back into the condenser
What are the mechanical vacuum jump trips?
350°F high discharge temperature - immediately stops
Main Steam Line HiHi radiation (trips to dryout)
26 inches Hg main condenser vacuum (trips to dryout)
Loss of voltage
Motor Protection
What channels of rad monitors will trip it?
A or C
What group isolations are associated with vacuum pumps?
Group 10
3x normal full power background on main steam line rad
Does the mechanical vacuum pump realign to condenser if it trips to dryout?
Yes
When is sjae placed into service?
500 - 800 psig
What cools the intercondenser?
PSW
Where does the 1st stage SJAE discharge to?
Intercondenser
Where does the 2nd stage SJAE discharge to?
Offgas
At what power are the mechanical vacuum pumps secured and why?
5% due to inadequate hold time and hydrogen build up in the turbine building
How long do the mechanical vacuum pumps run in dryout mode?
15 minutes