Multiple Dwellings Flashcards

1
Q

Multiple dwellings:

NLT floor areas had to be less than how many square feet

1916-1929?

After 1929?

A

2500

3000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Multiple dwellings:
NFP

Can you stretch lines up an aerial?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Multiple dwellings:
NFP

When should a roof line be used?

A

In a trench

Protect exposures

Extinguish what can’t be reached from below

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Multiple dwellings:
NFP

Line placement?

A

1st and 2nd lines via the interior stairs

The 3rd line should be via the fire escape or a rope stretch to a window

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Multiple dwellings:
NFP

What else should the officer carry besides normal compliment?

A

K tool

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Multiple dwellings:
NFP

When do you not have to open the windows?

A

Little heat and a tolerable smoke condition

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Multiple dwellings:
NFP

Where should you not throw material?

A

Roofs of setbacks or narrow shafts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Multiple dwellings:
NFP

Extra engine/truck?

2nd alarm?

3rd?

A

Extra engine/truck: Fire on two floors

2nd: progress not made on one floor in a short period; Fire extending into an exposure
3rd: fire extending into 2 exposures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Multiple dwellings:
NFP

Who tells the IC how the floors and apartments are designated?

A

First officer inside building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Multiple dwellings:
NFP

When can outside screen be used on an occupied building?

A

To protect people on a fire escape or for a heavy fire in a store

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Multiple dwellings:
NFP

Who can order the use of outside streams?

A

The ic, which can be a first arriving company officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Multiple dwellings:
NFP
OLT

How much hose should be brought to the fire floor for a well hole stretch?

A

At least the first length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Multiple dwellings:
NFP
OLT

When people are Trapped on the front fire escape, where should the lines go?

A

Stretch two lines, one stays in the street to protect the people and the other goes into the building to extinguish

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Multiple dwellings:
NFP
OLT

Who can order a line being shot across a shift into the fire building?

A

The IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Multiple dwellings:
NFP
OLT

Cellar fire: where do the first two lines go?

A

First line goes to the interior cellar entrance, the second line should advance down the stairs of an exterior entrance if there is one.

It can only go down the interior of the fires minor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Multiple dwellings:
NFP
OLT

What is the hose placement, size for a fire in a store?

A

Four large volume fire stretch a 2 1/2, Second wanna stretch to the entrance hallway if not needed there can go above

a charged line must be ready before the store is vented

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Multiple dwellings:
NFP
OLT

What is the preferred ladder for a stairway fire?

A

Extension

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Multiple dwellings:
NFP
OLT

What are the sprinkler requirements for SRO’s?

A

Sprinklers are required in each room, and the stairway. The system cannot be supplied by the fire department

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Multiple dwellings:
NFP
NLT

Cockloft access?

A

No means of entry. Has the fire potential of a lumber yard.

“Several feet” below the roof beams

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Multiple dwellings:
NFP
NLT

H-Type

What stairs allow access across the building?

A

Transverse via the public hall on all floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Multiple dwellings:
NFP
NLT

H-Type

What stairs have no hallway?

A

Isolated stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Multiple dwellings:
NFP
NLT

If pipe recesses are hot at roof level, then what must be checked?

A

The top floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Multiple dwellings:
NFP
NLT

Where will goosenecks not be found?

A

On the front or in the front courtyards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Multiple dwellings:
NFP
NLT

If stairs wrap around an elevator shaft, then how should you stretch?

A

Use a rope to the floor below

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Multiple dwellings:
NFP
NLT

H-Type

Where do you position an aerial in relation to the front entrance courtyard?

A

This area should be reserved for a TL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Multiple dwellings:
NFP
NLT

H-Type

What is the primary means of getting to the roof?

If conditions indicate who farms, then how do you get to the roof?

A

Wing isolated stairs in the same building, or stairway in an adjoining building

Aerial for rapid ascent.
(Top floor, shaft, two floors, or heavy fire)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Multiple dwellings:
NFP
NLT

H-Type

When should an extra engine and truck be called?

Second alarm?

A

Medium fire condition, 12 lines will be required.

Two floors involved, or extensive cockloft fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Multiple dwellings:
NFP
NLT

Do you need a line to pull ceilings at a cockloft the fire?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Multiple dwellings:
NFP
NLT

At a cock loft fire what apartments should you force?

A

All top floor ones

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Multiple dwellings:
NFP
NLT

When should you open a trench?

A

Only after that there is an adequate vent above the fire.

AND

When the fire reaches the inspection holes

(2 or more must be cut on the fire side)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Multiple dwellings:
NFP
NLT

How wide should a trench be?

A

At least 3 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

Multiple dwellings:
NFP
NLT

How far should the trench be from the initial vent hole?

A

20’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Multiple dwellings:
NFP
NLT

Can you operate a line into a trench?

A

Yes, to prevent fire from spreading

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

Multiple dwellings:
NFP
NLT

How deep are cocklofts?

A

As much as 4’ deep.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

Multiple dwellings:
NFP
NLT

What is the most probable point of fire spread?

A

Vertical steel Channel rails.

Also closets

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Multiple dwellings:
NFP
NLT

If second due truck is delayed, wha should the first truck do?

A

Send members to the floor above, if any fire is found immediately go to the top floor and check cockloft.

If fire is in the cockloft, line must be provided the top floor and the roof opened

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Multiple dwellings:
NFP
NLT

What does a fire escape in the throat indicate?

A

Two separate apts in the throat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Multiple dwellings:
FPMD:

Prior to designating the attack stair, how should everyone get to the fire floor?

A

Everyone should access it from the same stare

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

Multiple dwellings:
FPMD:

Who approves vertical ventilation?

Who approves horizontal ventilation?

A

IC

LCO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

Multiple dwellings:
FPMD:

When should ventilation of the fire apartment take place?

A

After the main body of fire has been controlled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

Multiple dwellings:
FPMD:

What is the SOP when in elevator not equipped with fire service is used?

A

Returned to the lobby unstaffed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

Multiple dwellings:
FPMD:

Who recalls the elevators whether or not they will be used?

Who ensures they have been recalled and searched?

A

First truck

Second truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

Multiple dwellings:
FPMD:

When should the doors to elevator machinery rooms be used for ventilation purposes?

A

Should not be used for vent until the fire is under control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

Multiple dwellings:
FPMD:

How many pounds should you consider each member?

A

275 (“572” backwards)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

Multiple dwellings:
FPMD:

Who enters the elevator when only one elevator that does not have fire service is available?

If the elevator does have fire service?

A

LCO, FE team, a CO with nozzle and control

Ov will take place of one of the engine FFs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
46
Q

Multiple dwellings:
FPMD:

Who operates the elevator when the OVM is involved in an outside operation?

A

Member from second truck or member designated by ic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
47
Q

Multiple dwellings:
FPMD:

Who designates a freight elevator safe to use?

A

The company officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
48
Q

Multiple dwellings:
FPMD:

Are elevators that open directly into apartments or foyers safe?

A

Should not be used by members

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
49
Q

Multiple dwellings:
FPMD:

Where should the elevators be maintained?

A

One in the lobby, and one 2 floors below the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
50
Q

Multiple dwellings:
FPMD:

When can you force adjoining apartments?

A

After the fire has been controlled, for high CO or severe smoke conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
51
Q

Multiple dwellings:
FPMD:

What door should you select for an area of refuge in the hallway?

A

One entirely on the same side of the building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
52
Q

Multiple dwellings:
FPMD:

Where is the fast unit and the CFR engine assigned?

A

Above the six floor = the floor below the fire

Sixth floor or below = determined by the I C

Fast truck should carry elevator keys

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
53
Q

Multiple dwellings:
FPMD:

What should the first engine officer announced via handy talkie?

A

When the initial hose line attack commences

54
Q

Multiple dwellings:
FPMD:

Who approves variations in stretching from stand pipes below? (Due to building configurations?)

A

Division commander’s, and it should enter into CIDS

55
Q

Multiple dwellings:
FPMD:

Who determines the attack stair?

Who do you inform of this designation?

A

LCO and ECO

Second engine, and the ic

56
Q

Multiple dwellings:
FPMD:

Does the attack stair need a standpipe?

A

No. Can we attach the stand pipe, and stretched on the floor below and then up the attack stair.

57
Q

Multiple dwellings:
FPMD:

Will the hose line provide sufficient cooling of a wind impacted fire?

A

No

58
Q

Multiple dwellings:
FPMD:

When can the control fire fighter of the first engine leave the stand pipe?

A

He remains throughout the operation

59
Q

Multiple dwellings:
FPMD:

When can the bulkhead door be vented?

A

After the main body of fire is controlled

60
Q

Multiple dwellings:
FPMD:

When should you use the fog tip for ventilation?

A

If the PPV fans are ineffective call for the fog tip and directed out an open window.

61
Q

Multiple dwellings:
FPMD:

Second engine company duties?

A

Bring post radio to the stand pipe with first hose is being connected

Ensure the Siamese is supplied

62
Q

Multiple dwellings:
FPMD:

Third engine company duties?

Where do they get extra hose?

A

Stretch a second line from usually two floors below via the attack.

Additional links should be here in between the last length of the second hose and the standpipe, obtained from the second or fourth engine

63
Q

Multiple dwellings:
FPMD:

Where do you charge the second line?

Who do you notify when doing so?

A

At the stairway door to the fire floor

The officer and control of the first line

64
Q

Multiple dwellings:
FPMD:

Duty of the fifth engine?

How did they stretch?

A

Hi rise nozzle. If they do not have one, they will contact dispatch and find out who has one at the scene.

Report to icp

Will either use the second line already in place, or stretch their own

65
Q

Multiple dwellings:
FPMD:

What does the CFR engine bring?

A

CFRD equipment, and FE tools

66
Q

Multiple dwellings:
FPMD:

Where does the first truck take the elevator to?

A

At least two floors below

67
Q

Multiple dwellings:
FPMD:

What door is the first truck responsible for controlling on the fire floor?

A

Both the attack and evacuation stairway doors

68
Q

Multiple dwellings:
FPMD:

If there is smoke or heat in the hallway, and unable to determine if it’s windy impacted, what does the first truck inside team do?

A

Officer and one member advances to the fire apartment door. Other member remains at attack door on the hallway side.

ECO stays on the stairwell side of the attack door

69
Q

Multiple dwellings:
FPMD:

What does the Ov bring?

A

The Halligan and the hook or axe

70
Q

Multiple dwellings:
FPMD:

If no fire service elevators, then what does the Ov do?

A

Proceeds to the fire floor, assists officer

71
Q

Multiple dwellings:
FPMD:

If New York city housing complexes do not have markings on the exterior apartments, who do you contact?

A

The local management office

72
Q

Multiple dwellings:
FPMD:

How does the roof man go to the apartment above?

A

Via the attack stairway

73
Q

Multiple dwellings:
FPMD:

Who ensures the LSR is being brought to the apartment above if there is a rope rescue?

A

IC

74
Q

Multiple dwellings:
FPMD:

Who orders deployment of curtain?

What does roof do once deployed?

A

The IC

Close the window on the ropes

75
Q

Multiple dwellings:
FPMD:

When does the LCC vent the stair bulkhead?

The elevator room?

A

Fire is knocked down

Fire is under control

76
Q

Multiple dwellings:
FPMD:

Who delivers the LSR if the roof man calls for it?

A

The LCC

77
Q

Multiple dwellings:
FPMD:

Can the LCC take a fire service elevator to the roof?

If there is no blind shift elevator then how does the LCC get to the roof?

A

Never take a fire service elevator that services all floors to go above the fire.

If no blind shaft elevator, take elevator to two floors below and go to roof via the evacuation stairway

78
Q

Multiple dwellings:
FPMD:

Who insurers all evacuation doors are closed on the fire floor?

A

The second truck

79
Q

Multiple dwellings:
FPMD:

What does the second truck do?

A

After searching hallway on fire floor, search the attack stairway for five floors above the fire

80
Q

Multiple dwellings:
FPMD:

Who coordinates the deployment of the curtain?

A

The second LCO

81
Q

Multiple dwellings:
FPMD:

What does the first roof man take?

The second?

A

Halligan Hydram and curtain

Halligan maul and LSR

82
Q

Multiple dwellings:
FPMD:

What does the third roof do?

A

Go to the apartment above with a curtain and tools

83
Q

Multiple dwellings:
FPMD:

What does the third truck generally do?

A

Conduct searches of stairways and hallways when there is severe smoke above the fire sector

84
Q

Multiple dwellings:
FPMD:

What does the fourth truck usually do?

A

Assist or initiate searches on upper floors and stairs as determined by the I C

85
Q

Multiple dwellings:
FPMD:

What does the sixth truck do?

A

The vent support group

86
Q

Multiple dwellings:
FPMD:

What is the priority order of the PPV fans?

A

Pressurize the attack

Pressurize the evacuation

Ventilate the public halls

87
Q

Multiple dwellings:
FPMD:

Who delivers the blanket to the floor below

A

Squad

88
Q

Multiple dwellings:
FPMD:

When does the first ECC connect a 3 1/2 to the Siamese

A

If any evidence of fire is present

89
Q

Multiple dwellings:
FPMD:

When should a second 3 1/2 be stretched to the Siamese?

When should a second or third supply line be connected to a lower floor stand pipe?

A
  1. More than one line is being used from the standpipe

System seems to not be receiving enough water volume or pressure

A no flow on the flow meter indicates a valve is closed in the system

  1. Control valve stuck between Siamese and riser

Leak in piping system below grade

Foreign matter obstructions in the Siamese inlets

Not enough pressure

90
Q

Multiple dwellings:
FPMD:

What could a door with no letter or number designations on a floor mean?

A

They could be a second exit from an apartment

91
Q

Multiple dwellings:
FPMD:

If a balcony blocks the high-rise nozzle, what other options do you have?

A

An adjoining window from the floor below

From the balcony railing deflecting off the underside of the balcony above the fire apartment

92
Q

Multiple dwellings:
FPMD:

When should you use a search line in a basement?

A

Motor vehicle fires in the cellar

93
Q

Multiple dwellings:
FPMD:

When can you use a standpipe in a Lou of a hand stretch into a below grade area?

A

When the fire is controlled by a sprinkler, and members would not be exposed to an idlh

94
Q

Multiple dwellings:
FPMD:
Low rise:

When should the bulkhead be vented at a lower rise?

A

Early in the operation with approval of the IC

95
Q

Multiple dwellings:
FPMD:
Low Rise:

When should an inch and three-quarter be stretched from the pumper?

When should a 2 1/2 inch be stretched from the pumper?

A

Every apartment door is within 50 feet of every stairway

Any apt door is more than 50 feet from a stairway

96
Q

Multiple dwellings:
FPMD:
Low Rise:

Who determines the attack stair in a low rise?

A

The LCO

97
Q

Multiple dwellings:
FPMD:
Low Rise:

Which stair does the roof man take to get to the roof?

A

The evacuation

98
Q

Multiple dwellings:
FPMD:
Low Rise:

What does the OV take?

What does the LCC take?

A

Halligan and Halligan hook

Halligan and axe

99
Q

Multiple dwellings:
FPMD:
Low Rise:

What can a 35 reach?

A

Usually the fourth floor

100
Q

Multiple dwellings:
FPMD:
Low Rise:

If no outside ops, what does the Ov and LCC do?

A

Go to the fire floor, or may be directed to the apartment above when second due is delayed

101
Q

Multiple dwellings:
FPMD:
Low Rise:

What does the roof man take?

A

Halligan, Halligan hook and LSR

102
Q

Multiple dwellings:
FPMD:
Low Rise:

What is the priority order of roof access?

A

Attached adjoining building stairway

Enclosed evacuation stairway

Aerial or tower

103
Q

Multiple dwellings:
FPMD:
Low Rise:

If one open interior stair, how does roof man get to the roof?

A

If area is not an IDLH, fire apartment door is controlled and maintain closed.

If it is in ID LH, then he must be teamed up with another member.

Both cases: apartment door must be closed until roof tells officer they are on roof and bulkhead is closed.

They remain there until the fire is under control

104
Q

Multiple dwellings:
FPMD:
Low Rise:

What does the inside team of the second truck bring?

Where do they go?

A

KO curtain

Apartment directly above. Responsible for all floors and stairs above the fire

105
Q

Multiple dwellings:
FPMD:
Low Rise:

At a top floor job, where does the second truck go?

A

The fire floor with first truck.

Second roof brings the the KO curtain to the roof

106
Q

Multiple dwellings:
FPMD:
Low Rise:

What does the second roof bring?

A

Halligan, Halligan hook, and LSR. (Same as first due)

**Top floor fire bring curtain instead of LSR

107
Q

Multiple Dwellings:
Wind impacted fires:

What are the five conditions that must be present for a wind impacted fire?

A

WOOFF

Wind
Open apt door
Open window
Fire
Flowpath: open stairwell door or apt door across hall
108
Q

Multiple Dwellings:
Wind impacted fires:

When does size up begin for a wind impacted fire?

A

Before the tour starts, knowing forecasted weather

109
Q

Multiple Dwellings:
Wind impacted fires:

What stairwell should members access the floor from prior to establishing attack stair?

A

The same stairway for all members

110
Q

Multiple Dwellings:
Wind impacted fires:

Deployment of a wind controlled device will have what effects?

A

Reduction of:
Heat
Fire intensity
Visibility

Increase of:
Smoke

111
Q

Multiple Dwellings:
Wind impacted fires:

What must you do once deploying the curtain?

A

Close the window

112
Q

Multiple Dwellings:
Wind impacted fires:

What increases once advancing a hose line into an apartment with a curtain deployed?

A

Heat

113
Q

Multiple Dwellings:
Wind impacted fires:

Where should you direct an exterior stream into the window?

A

At the ceiling

114
Q

Multiple Dwellings:
Wind impacted fires:

Deployment of the high-rise nozzle will improve or make worse conditions in the public hall?

A

Improve

115
Q

Multiple Dwellings:
Wind impacted fires:

When flanking through an adjoining wall, where should the whole be made?

A

As close to the exterior wall as possible

116
Q

Multiple Dwellings:
Wind impacted fires:

When using a flanking strategy when door to the fire apartment is open, how do you stretch to the adjoining apartment?

A

To the adjoining apartment via the window from the apartment below using a utility rope.

**Door to this apartment must remain closed

117
Q

Multiple Dwellings:
Wind impacted fires:

When the fire door is left open, Members must stay in the stairwell until confirmation of what?

A

WCD is deployed and secured and/or FIRE IS CONTROLLED by HRN exterior stream or flanking strategy

118
Q

Multiple Dwellings:
Wind impacted fires:

What is normally the first tactic used to control wind impacted fire?

A

KO

119
Q

Multiple Dwellings:
Wind impacted fires:

Once alternate strategy implemented, who enters the hallway?

A

**ALL THREE TRUCK MEMBERS

LCO and one member gain control of fire apt door, and other member stays on hallway side of stair door.

Engine officer on stairwell side of stair door.

120
Q

Multiple Dwellings:
Wind impacted fires:

Who decides to enter the fire apartment?

Who enters first?

A

Ic and or fire sector.

Engine company

121
Q

Multiple Dwellings:
Wind impacted fires:

Who should the engine officer contact before entering the fire apt?

A

Roofman:

DLR

Description of apt
Location of fire
Route to take

122
Q

Multiple Dwellings:
Wind impacted fires:

Apartment door closed and window has failed: where is the line charged?

Who enters apt first?

A

Advanced to fire apartment door and then charged

Engine company

123
Q

Multiple Dwellings:
Wind impacted fires:

Fire apartment door closed and window has not failed: should a wind control device be deployed?

A

IC may decide to deploy before failure. However it should be ready for immediate deployment

124
Q

Multiple Dwellings:
Wind impacted fires:

Fire apartment door closed and window has not failed: who enters the apartment first?

A

ALL THREE TRUCK MEMBERS

Officer and one member at their apartment to search, other members stays at fire apartment door inside the apartment.

125
Q

Multiple Dwellings:
Wind impacted fires:

Fire apartment door closed and window has not failed: who orders the charge hose line advanced into the fire apartment?

When should generally not advance until?

A

LCO requests the hose line advanced.

Main fire area has been located and if possible confined

126
Q

Multiple Dwellings:
Wind impacted fires:

Known life hazard: What conditions must be met in order to attempt a rescue?

A

Must be while alternate strategy is being implemented;

IC must be notified prior to;

IC must be notified of the stairway from which they are operating

**If operation is close to apartment door, try closing it

127
Q

Multiple Dwellings:
NYCHA Entry:

What will the key fob give you access to?

If it fails to give you access, then what should you do?

A

Grant access to all NYCHA buildings

Call NYCHA emergency number for remote unlocking

128
Q

Multiple Dwellings:
NYCHA Entry:

If building loses power how do you open the door?

A

Special key which is not issued to units; requested from building management office

129
Q

Multiple Dwellings:
NYCHA Entry:

If you force a door or elevator door and are able to secure it do you need to notify anyone?

A

Yes must notify housing via dispatcher, and letterhead to the chief of ops

130
Q

Multiple Dwellings:
NYCHA Entry:

If you lose key fob what should you do?

A

Call housing emergency number and provide serial number. Housing will deactivate that key fob.

**Housing issues a new one

**FS – 112 is not required for lost or damaged key fobs

131
Q

Multiple dwellings:
FPMD:

First roof man toolset?

Second roof man toolset?

A

Halligan, hydra ram, curtain

Halligan, maul, LSR