Main Turbine Purpose?
-Receives high pressure steam form the main steam system and converts the thermal energy of the steam into mechanical energy used to turn the main generator.
Hp Turbine
Steam enters how? How many stages? First stage pressure is? Used for? Steam Exits?
- Steam enters through 2 stop valves and 4 governor valves.
- 9 stages (18 total)
- First stage pressure is ~800psi, used for Tref
- Exits into 4 exhaust (2 at each end)
Gland Sealing Steam System
purpose? Pressure?
- Prevents Leakage of air into steam turbine and steam from leaving turbine.
- Pressure maintained between 3-6psig
Gland Steam Condenser and Air Exhausters
Purpose? Power supply?
- Condenser takes the exhaust of the gland steam system and uses it to reheat Condensate.
- Air exhausters discharge air and other noncondensable vapors to the atmosphere
- powered from MMC-4
Cylinder Heating Steam is what pressure?
-Maintained 5psig above Hp last stage pressure
Turbine Lubricating Oil System purpose?
- Provides oil at presure for lubrication and cooling of Turbine generator bearings and turning gear.
- Backup supply for generator seal oil.
Main Turbine Oil Pump
Power supply?
-Shaft driven.
AC Turning Gear and Seal oil Back-up pumps
Purpose? Power supply? Comes on at? Located?
- During startup and shutdown periods when the Main Turbine Oil Pump cannot be used, this supplies all oil requirements
- Can supply Seal oil backup for generator
- Powered from MCC-14/MCC-20
- Both pumps start at 8-10psig bearing oil pressure
- Located on top of Lube OIl Reservoir tank
DC Emergency Oil Pump
Purpose? Location? Power Supply? Auto starts on?
- Emergency backup for the AC turning gear oil pump
- South of AC turning gear pump
- MCC-C
- Loss of power to AC Turning gear pump/ Low bearing oil pressure 5-8 psig
Vapor Extractor for Main Lube Oil Reservoir
Purpose? Power supply? Location?
- Used to eliminate vapors and maintain negative pressure on reservoir
- Powered from MCC-4
- Top of Reservoir
Kaydon Lube Oil Filtration system power supply?
-480V Bus 3