LOT 202.18 Generator Seal Oil Flashcards
- LOT 202.18 Generator Seal Oil*
- *
Where can the Seal Oil Pumps be operated from?
- *Locally (29’ TGB)**
- No controls for Seal oil pumps in MCR*
- LOT 202.18 Generator Seal Oil*
- *
What collects H2 leakoff in the Generator Seal Oil System?
Defoaming Tanks
H2 then drains to H2 Receiver Tank
- LOT 202.18 Generator Seal Oil*
- *
When is Generator Seal Oil required to be in operation?
H2 in the generator
Main Turbine shaft spinning
- LOT 202.18 Generator Seal Oil*
- *
What pressure does the Air Side Seal Oil Pump (ASSO) maintain the generator seal oil system normally operate at?
- *87 psig**
- 12 psig > than H2 pressure (75 psig)*
Pressure equalizing valves maintain Air side and Oil side at the same pressure.
- LOT 202.18 Generator Seal Oil*
- *
What pressure does the HSSO D/P Regulator, ASSO D/P regulator, and the Turbine Backup Pressure Regulator maintain?
- ASSO D/P Regulator:*
- *12 psid**
- 5 psid starts DC Pump*
- Turbine (ASSO) Backup Pressure Regulator:***
- *8 psid**
- Supplied from Turbine LO*
Note:
If supplying air side seals from the BOP in the TGLO System, must reduce H2 pressure to < 2 psig.
- LOT 202.18 Generator Seal Oil*
- *
What cools the HSSO and ASSO Coolers?
CL-ACW
Maintains 100 ˚F - 120 ˚F
Note:
Maintained within 4 ˚F of ASSO.