LOT 202.18 Generator Seal Oil Flashcards

1
Q
  • LOT 202.18 Generator Seal Oil*
    • *

Where can the Seal Oil Pumps be operated from?

A
  • *Locally (29’ TGB)**
  • No controls for Seal oil pumps in MCR*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 202.18 Generator Seal Oil*
    • *

What collects H2 leakoff in the Generator Seal Oil System?

A

Defoaming Tanks

H2 then drains to H2 Receiver Tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 202.18 Generator Seal Oil*
    • *

When is Generator Seal Oil required to be in operation?

A

H2 in the generator

Main Turbine shaft spinning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • LOT 202.18 Generator Seal Oil*
    • *

What pressure does the Air Side Seal Oil Pump (ASSO) maintain the generator seal oil system normally operate at?

A
  • *87 psig**
  • 12 psig > than H2 pressure (75 psig)*

Pressure equalizing valves maintain Air side and Oil side at the same pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • LOT 202.18 Generator Seal Oil*
    • *

What pressure does the HSSO D/P Regulator, ASSO D/P regulator, and the Turbine Backup Pressure Regulator maintain?

A
  • ASSO D/P Regulator:*
  • *12 psid**
  • 5 psid starts DC Pump*
  • Turbine (ASSO) Backup Pressure Regulator:***
  • *8 psid**
  • Supplied from Turbine LO*

Note:
If supplying air side seals from the BOP in the TGLO System, must reduce H2 pressure to < 2 psig.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • LOT 202.18 Generator Seal Oil*
    • *

What cools the HSSO and ASSO Coolers?

A

CL-ACW

Maintains 100 ˚F - 120 ˚F

Note:
Maintained within 4 ˚F of ASSO.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly