LOT 201.40 AMSAC Flashcards

1
Q
  • LOT 201.40 AMSAC*
    • *

What powers AMSAC?

A
  • AMSAC:*
  • *DP006**
  • SGNR Level Instruments:*
  • *LT-0518/0528: DP1203**

LT-0537/0547: DP1204

Physically located in QDPS RPU-N (35’ EAB Relay Room)

Note:
Instruments fail low on loss of power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 201.40 AMSAC*
    • *

When will AMSAC actuate?

A

SGNR Level ≤ 15% [1/1 on 3/4] [25 sec TD]

Initiates:

  • Turbine Trip
  • Aux Feed Actuation
  • Blowdown Isolation
  • SG Sampling Isolation

Note:
Armed if ≥ C-20 (≥ 30% Impulse Pressure) [2/2] ≈ 40% RTP

  • Peak pressure not a concern if < 70% RTP
  • Stays armed for 360 sec after falling below 30% impulse pressure
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 201.40 AMSAC*
    • *

What is the design basis casualty for AMSAC?

A

Loss of Feedwater with no RPS Actuation

  • PZR PORVs, Rx Trip, Turbine Trip, SG Safeties, and AFW still function.
  • Peak pressure: 2833 psig
    • Emergency Pressure limit is 3200 psig

Note:
Protected as long as turbine trips in 30 secs and AFW starts in 60 secs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly