LOT 202.24 CL-ACW Flashcards
- LOT 202.24 CL-ACW*
- *
Where are the CL-ACW components physically located?
- 29’ TGB:*
- *Pumps (3)**
- SW Corner*
- *SW/FW HX (2)**
- SW Corner*
- *IA Emergency Pump**
- N of CARS pumps*
- 55’ TGB:*
- *Chem Add Tank**
- SW Corner*
- 83’ TGB:*
- *Surge Tank**
- SW Corner*
- LOT 202.24 CL-ACW*
- *
What provides makeup to the CL-ACW Surge Tank?
Demin Water
- Auto makeup at < 50%
- *
Note:
N2 blanket (5 psig)
- LOT 202.24 CL-ACW*
- *
What cools CL-ACW?
OL-ACW
HXs are 60% capacity
- LOT 202.24 CL-ACW*
- *
What chemical do we add to the CL-ACW system?
NALCO SureCool
- LOT 202.24 CL-ACW*
- *
What will auto start/trip the CL-ACW pumps?
Auto Starts:
Discharge Header Pressure - Low (60 psig)
Trip of running pump
- Trips:*
- *Ground Fault**
Overcurrent
Undervoltage
Controlled from CP009/Local
Note:
SW/FW HX Common discharge pressure on CP009 NOT pump discharge pressure.
- LOT 202.24 CL-ACW*
- *
What does CL-ACW cool?
Turbine:
EHC (120 ˚F)*
Air Side Seal Oil (105 ˚F)*
H2 Side Seal Oil (105 ˚F)*
Exciter Coolers (113 ˚F)*
Isophase
Stator Cooling Water (105 ˚F)*
Feed / Condensate:
Condensate Pump Bearings
Feed Booster Pump Bearings / Lube Oil
SUFW Seals / Lube Oil*
TCV closes at low temps
Misc:
IA Compressors (11/12/13)
After Cooler / Lube Oil
Secondary Sampling
MSDT pumps Seal Water
CARS
Note:
Coolers have automatic TCVs