Lifesaving Equipment Examination Flashcards
1
Q
Examine Lifejackets
A
- Verify quantity
- Verify Approvals
- Verify Lights
- Verify Whistle
- Verify Retro-reflective tape
- Verify Stowage
2
Q
Examine Immersion Suit and Stowage
A
- Verify quantity
- Verify Approvals
- Verify Stowage
3
Q
Examine Line Throwing Appliance
A
- Verify Presence
- Examine instructions or diagrams illustrating use
- Verify age of pyrotechnics
- Verify Stowage
4
Q
Examine Pyrotechnics
A
- Verify Number
- Verify Stowage
- Verify condition/serviceability
5
Q
Examine quick release life buoys
A
- Verify number and location
- Verify size
- Verify presence of self-igniting lights
- Verify condition/serviceability of self activating smoke signals
6
Q
Examine Life Buoys
A
- Verify type approvals
- Verify quantity
- Verify markings
- Examine attachments and fittings
- Verify size/weight
7
Q
Examine Lifeboat
A
- Verify required number (one on each side for the total number of crew)
- Verify stowage arrangements
- Verify markings
- Verify presence of required equipment
- Examine release gear(s)
- Verify instructions inside for release gear
- Witness operational test of engine (run for at least 3 mins)
- Witness operational test of rudder
8
Q
Examine Muster and Embarkation stations
A
- Examine arrangements
- Verify embarkation ladders meet requirements
- Verify emergency lighting configuration and operation
- Verify performance of emergency lighting tests
9
Q
Examine Liferafts and installations
A
- Verify type approval
- Verify liferaft capacity requirements
- Verify Stowage
- Evaluate launching arrangements (sunny side up)
- Verify Markings
- Verify condition
- Verify annual service dates
10
Q
Examine Rescue Boat
A
- Verify required number
- Verify embarkation and launching arrangements
- Verify presence of equipment
- Verify stowage
- Witness operational test of engine
11
Q
Examine Boat Davit ( rescue and lifeboat)
A
- Examine condition of davit(s) and associated components
- Witness functional test of davit limit switch
- Witness operational test of falls
- Verify falls renewed at an interval or not more than 5 years
12
Q
Examine General Emergency Systems
A
- Verify alarm activation points
- Verify operational test of audible general alarms signals
- Verify connection to emergency power source
- Verify public address system is audible
- Verify general alarm system tests