IFSTA Chapter 13 Water Shuttle Operation Flashcards
Per NFPA 1901 Water Tenders (Tankers) must be rated at a fill rate of at least?
1000 gpm
Why would LDH provide little advantage at a fill site operation
Due to remaining water in the hose causing it to be extremely heavy and hard to manouver
On Gravity Tankers how big is the opening where the water is dumped from
8” or larger
Fill Site pumper rating minimum per NFPA 1901
1000 gpm
Optimum Route Arrangement for a water shuttle
Circular Route
Goal of the fill site
Load tankers as safely and efficiently as possible
NFPA 1901 minimum dump capability for a tanker
1000gpm for the first 90% of the tanks capacity
Foldable Tank ground placement recommendations and minimum capacity
Surface that is level as possible and be
atleast 500 gallons higher than that of the apparatus filling it up
When are multi fill tanks operations needed and what is the goal of this operation
Fires with Flow rates in excess of 300 gpm and the goal is to keep the tank from which the attack pumper is drafting from full at all times
Prior to concluding operations all attack apparatus and dump site pumper should be?
Refilled prior to picking up drafting pits and drafting equipment
Tankers only drop and pick up 90% of its load capacity, what formula is used to calculate water shuttle flow rate
Flow= (.9 x TS) / Trip Time
TS: Tank Size