IBC Chapter 5 Flashcards
- Premises must be identified by numbers or addresses visible from the street, with a minimum character height of at least inches.
A. three
B. four
C. six
D. eight
- B Sec. 502.1
- Building height is measured to the .
A. average height of the highest roof surface
B. highest point of the highest roof surface
C. average height of all of the roof surfaces
D. highest point of the lowest roof surface
- A Sec. 202
- The tabular allowable height and building area per story for a fully-sprinklered Group I-2 occupancy of Type IB construction is stories and square feet.
A. 4, 40,000
B. 3, 60,000
C. 5, unlimited
D. unlimited, unlimited
- C Tables 504.4, 506.2
- What is the maximum tabular allowable height, in feet, for a nonsprinklered Group B occupancy of Type IIA construction?
A. 50
B. 55
C. 65
D. Unlimited
- C Table 504.3
- Basements do not need to be included in the total allowable area of a single-occupancy building, provided the total area of such basements do not exceed .
A. one-third the floor area permitted for any single story
B. the area permitted for a one-sto1y above grade plane building
C. twice the area permitted for a single story
D. the tabular area based on construction type and occupancy group
- B Sec. 506.1.3
- A story is considered a story above grade plane where the finished surface of the floor above is more than feet above grade plane.
A. 3
B. 4
C. 5
D. 6
- D Sec. 202
- Incidental uses shall not occupy more than percent of the building area of the story in which they are located.
A. 5
B. 10
C. 15
D. 20
- B Sec. 509.3
- What is the maximum allowable height in feet above grade plane for a fully sprinklered Type IIA building housing a Group I-2 occupancy?
A. 55 feet
B. 65 feet
C. 75 feet
D. 85 feet
- D Table 504.3
- What is the maximum allowable number of stories above grade plane for a fully-sprinklered IIIB building housing a Group I-2 occupancy?
A. 0, it is not permitted
B. 1
C. 2
D. 3
- A Table 504.4
- Combustible steeples are limited to a maximum height of feet above the allowable building height.
A. 15
B. 20
C. 30
D. 40
- B Sec. 504.3, Exc.
- The area of a mezzanine is not to be included in the determination of the .
A. fire area
B. building area
C. occupant load
D. plumbing fixture count
- B Sec. 505.2
- A minimum clear height of is required above and below mezzanine floor construction.
A. 6 feet, 8 inches
B. 7 feet
C. 7 feet, 6 inches
D. 8 feet
- B Sec. 505.2
- In general, the aggregate area of mezzanines within a room is limited to of the area of the room in which the mezzanines are located.
A. 10 percent
B. 25 percent
C. 33 1/3 percent
D. 50 percent
- C Sec. 505.2.1
- Portions of a mezzanine need not be open to the room in which the mezzanine is located, provided the enclosed space is limited in size to a maximum of of the mezzanine area.
A. 10 percent
B. 25 percent
C. 33 1/3 percent
D. 50 percent
- A Sec. 505.2.3, Exc. 3
- A mezzanine is not required to be open to the room in which it is located where the occupant load of the enclosed space does not exceed .
A. 10
B. 20
C. 30
- A Sec. 505.2.3, Exc. 1
- An allowable area increase for frontage is not permitted where a maximum of of the building perimeter is sufficiently open.
A. 10 percent
B. 25 percent
C. 33 1/3 percent
D. 40 percent
- B Sec. 506.3.1
- In order to be considered as sufficiently open for an allowable area increase for frontage, the public way or open space must have a minimum width of feet.
A. 10
B. 20
C. 25
D. 30
- B Sec. 506.3.2
- What is the maximum tabular height, in number of stories above grade plane, for a Group R-1 occupancy of Type IIB construction where the building is protected by an NFPA l3R sprinkler system?
A. 3
B. 4
C. 5
D. 6
- B Table 504.4
- What is the maximum allowable building area factor for a nonsprinklered Type VB building housing a Group B occupancy?
A. 9,000 square feet
B. 12,000 square feet
C. 27,000 square feet
D. 36,000 square feet
- A Table 506.2
- The maximum permitted aggregate area of mezzanines, per story, in a Type IIB building provided with a sprinkler system and an emergency voice/alarm communication system is of the floor area of the room.
A. one-third
B. 50 percent
C. two-thirds
D. 75 percent
- B Sec. 505.2.1, Exc. 2
- In order to reduce the required open space surrounding certain unlimited area buildings from 60 feet to 40 feet, walls facing the reduced open space shall have a minimum fire-resistance rating of .
A. 5 minutes
B. 1 hour
C. 2 hours
D. 3 hours
- D Sec. 507.2.1, #2
- What is the maximum allowable number of stories above grade plane permitted for a Type IIIA building housing a Group R-2 occupancy that is provided with a l 3R sprinkler system throughout?
A. 2
B. 3
C. 4
D. 5
- C Table 504.4
- In order for a Group E building to comply with the unlimited area allowances of Section 507, the building’s construction type cannot be Type .
A. IIA
B. IIB
C. IIIA
D. IIIB
- D Sec. 507.11
- A complying Group H-2 aircraft paint hangar may be unlimited in floor area when limited to one story, provided the hangar is surrounded by yards or public ways having a minimum width of .
A. 40 feet
B. 60 feet
C. twice the height of the hangar
D. one and one-half times the height of the hangar
- D Sec. 507.10