Gypsum Construction Handbook Flashcards
- __________fastener should be used when 3/8”, ½” and 5/8” single layer gypsum panels are attached to wood framing.
A. 1-1/2” Type G bugle head
B. 1-1/4 Type S bugle head
C. 1-1/8” Type S bugle head
D. 1-1/4” Type W bugle head
- D Page 39
- __________is/are warning signs of fastener imperfections.
A. Darkening
B. Localized cracking
C. Protrusion of the fasteners
D. All of the above
- D Page 370
- Extended periods of ________ will discolor panel face paper.
A. High humidity
B. Low humidity
C. Cold weather
D. Strong sunlight
- D Page 355
- ⅜-inch gypsum panels are designed for framing centers up to ________.
A. 24 inches
B. 16 inches
C. 20 inches
D. 12 inches
- B Page 3
- _________is often caused by excessively fast drying of joint compounds.
A. Loose panels
B. Board sagging
C. Joint cracking
D. None of the above
- C Page 370
- Use ______screw to connect ¾ inch single-layer panels to steel studs.
A. 1 inch Type S bugle head
B. 1⅛ inch Type S bugle head
C. 1¼ inch Type S bugle head
D. 2¼ inch Type S bugle head
- C Page 38
- Stack panels face up with ends resting on nominal 2” x 4” lumber and with center of the boards resting on floor, and allow to remain overnight or until they have ________.
A. A 1” space between adjacent panels
B. At least a 2” permanent bow
C. No stains or discoloration on face paper
D. All of the above
- B Page 112
- Maintain and control heat in the range of 55°F to 70°F 24 hours ________the entire gypsum board finishing process.
A. Before
B. During
C. After
D. All of the above
- D Page 103
- Board sags in ceiling are often caused by ______.
A. Improperly fitted panels
B. Insufficient support of board
C. High-humid conditions
D. All of the above
- D Page 371
- Long partition runs shall have _________to compensate for hygrometric and thermal expansion.
A. Relief joints
B. Expansion joints
C. All the above
D. Control joints
- D Page 358
- All but ________will cause cracking of compound joints in veneer plaster finishing.
A. Maximum air circulation
B. Rapid drying
C. Possible shrinkage
D. All of the above
- D Page 355
- Maximum frame spacing for ⅜ inch single-layer ceiling application is ________o.c.
A. 12 inches
B. 16 inches
C. 24 inches
D. In compliance with local building codes
- B Page 73
- Where single-nailing is used, drive nails at least________ inch(es) from ends or edges of gypsum board.
A. ¼ inch
B. ⅝ inch
C. ½ inch
D. ⅜ inch
- D Page 108
- Joint defects generally occur in a straight-line pattern and in most cases result from ________.
A. Incorrect framing
B. Incorrect joint treatment
C. Climatic conditions
D. All of the above
- D Page 370
- Wood furring strips over wood framing shall be ______minimum size for nail-on application.
A. 1” x 1”
B. 1” x 2”
C. 1” x 3”
D. 2” x 2”
- D Page 90