General Flashcards
List all Flight Deck Emergency Equipment
Captain: Flashlight, 2 Life Vests, CB’s, Rope
FO: Flashlight, Life Vest, CB’s, Rope, and Gear and RAT Pins
Observer: Seat, Headset, O2
Doorway: Crash Axe, PBE, Halon Extinguisher
After turning Batteries 1 and 2 to “ON” and “AUTO,” what three things are we looking for? Limitation?
Screen 2, 3 & IESS on. Airplane must not be moved until IESS is initialized within 90 seconds
Under what voltage must a “battery recharge procedure” be accomplished? Under what voltage must maintenance be called?
22.4-21.0 volts. Less than 21.0v
Why is it important to wait approximately 30 seconds after energizing the batteries before running the fire extinguisher panel test?
To verify there are no fire protection fail messages on the EICAS
List all items that are part of the fire extinguisher panel test.
Six fire protection lights
5 EICAS message
2 ITT Indications
2 Warning Lights
2 Aural Warnings
What else do we need to do when establishing AC power to the aircraft?
Nav lights on (logo too if at night), PACKS set to attendant. PACKS should be OFF when a ground air conditioning source is being utilized.
Recite Callouts for Engine Start
“Starting Engine 1 (2)” “Normal Start”
Recite callouts when entering the runway
“Runway ____ Confirmed” “Checked”
Understand Fuel Trend Monitoring. How are they determined? Is it against policy to land underneath?
Takes place upon reaching TOC and at least for every hour thereafter. It is NOT a violation to land underneath values
Recite/Define Minimum Fuel
Cannot accept any undue delay, 45minutes endurance 1500 AFE green dot clean, 2250lbs
Recite/Define Emergency Fuel
Will be landing with less than 30 minutes of fuel, 1500 AFE green dot clean, 1500lbs
Hold fuel VS reserve fuel
Hold fuel: planned landing weight and 10,000 AFE destination
Reserve fuel: 45 minutes of TOD fuel burn rate. Will never be less than 2450lbs