Fuel Flashcards

1
Q

How many integral wing tanks are there?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many tanks are in each integral wing tank and what is each section called?

A

2:
- collector tank
- surge tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the purpose of the collector tank?

A

Keeps the fuel pumps submerged thus ensuring constant fuel flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the purpose of the surge tank?

A

To collect any fuel that may enter the vent system during wing down and uncoordinated manoeuvres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many water drains valves are there?

A

One per tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many magnetic level indicators are there?

A

3 per wing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the capacity of each tank?

A

6550kg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What fuel pumps does each integral tank contain?

A

1 ejector fuel pump
1 ac electric fuel pump
3 scavenge pumps
1 DC fuel pump (right wing only)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How does the ejector fuel pump work?

A

Venturi effect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the purpose of the AC electric fuel pumps?

A

Act as backup for the respective ejector pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What BUSSES are the AC electric pumps powered by?

A

AC pump 1 = AC BUS 1
AC pump 2 = AC ESS BUS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are the purpose of the scavenge pumps?

A

To maintain the fuel level in the collector tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the purpose of the DC fuel pump?

A
  • Provides pressurised fuel for normal APU operation
  • engine start when there is no AC power or the AC fuel pump is not working
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What happens when the cross feed selector knob is changed to LOW 1/2?

A

LOW 1 = cross feed valve opens and AC pump 2 activates
LOW 2 = cross feed valve opens and AC pump 1 activates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When does a fuel imbalance message appear on the EICAS and when does this disappear?

A

Appears when fuel balance is over 360kg and disappears when it reduces to less than 45kg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When do the fuel shutoff valves close?

A

When the fire handle is pulled