Fire Protection Flashcards
When should you test the fire detection system?
FFOD in a new airplane
What areas have fire protection?
Engine 1 Engine 2 APU Forward Cargo Aft Cargo Lavatories
How long after an APU fire is detected will the shutoff valve be automatically closed?
10 seconds
What happens when the fire extinguisher handle is pulled?
Fuel shutoff valve is close
Hydraulic shutoff valve is closed
Bleed shutoff valve is closed
What is the procedure for annunciated forward cargo fire?
Press forward cargo fire extinguisher button once to discharge Halon
What happens when the fire detection handles are pulled?
Turns off: Bleed air SOV Fuel SOV Hydraulic SOV Arms Fire Extinguishing bottles
What does the APU EMER STOP button do?
Closes FUEL SOV
When will the APU automatically shut down in flight?
UFO
Underspeed
FADEC Fult
Overspeed
When will the APU shutdown automatically on the ground?
UFO SHELF
Underspeed
FADEC Fualt
Overspeed
Sensor Fail High Oil Temp EGT Over Temp Low Oil Pressure Fire
If a fire is detected in the APU and is automatically shut down what will happen after 60 seconds?
The Fire Extinguisher light turns on
How many smoke detectors do we have in the forward cabin?
3
How many smoke detectors do we have in the aft cargo?
2
How many fire bottles do we have for the cargo compartments?
2
High rate
Low rate
If there is an annunciated cargo fire in flight, how many times do you have to press the fire extinguisher button to discharge HIGH and LOW bottles?
Once
If there is an annunciated cargo on the ground how many times do you need to press the fire extinguisher button?
Once for high
Twice for low
How many times do you need to press the fire extinguisher button for an un annunciated fire on the ground?
Once to arm
Twice for high
Thrice for low