Final Exam Oxygen Review Flashcards
What are the two types of oxygen systems on airplanes ?
Stored Gas Chemical/solid state
What are the parameters of a High Press. Oxygen bottle?
- 1800 - 2400 psi
- Green
- Labeled “Aviators Breathing Oxygen” stenciled in white 1” letters
What are the parameters of a Low Press. Oxygen bottle?
- 450 psi
- Yellow
- Labeled “Aviator’s Breathing Oxygen”
What are the three types of Green (HP) Oxygen bottles
DOT 3AA 1800
DOT 3HT 1800 (thinner wall)
DOT E8162 Aluminum lined with kevlar overwrap
What is the hydrostatic testing interval for DOT 3AA 1800?
Tested every 5 years
What is the Hydrostatic testing intervals for DOT 3AA 1800 with the thinner wall?
Tested every 3 years (max 24 year life)
What is the testing interval for DOT E8162 aluminum-kevlar?
Tested every 3 years and maximum 15 year life
What is important to keep in mind when replacing oxygen bottles?
Make sure replacement bottle is same size and weight as the one removed, as brackets may not be strong enough for a heavier bottle