From a firefighting standpoint what is the major weakness of PD’s?
The open unenclosed stairway
At a fire in the attic of a PD, the access to the attic is via a pull down stair, can you use these or do you need to call for a portable ladder?
The pull down stairs should not be used, a portable ladder should be used
At the side of a PD there are two doors, one door is at ground level the other had a stoop. What can you expect on the other side of these doors?
Ground level door will usually be on a small landing where you can do down to the basement or up to the kitchen.
Door with stoop is usually leads to a stair case for access to the second floor
At a fire in a pd there is a porch with a roof, can you use this porch roof to access the windows?
Yes if it is of normal construction, do not use if lightweight or aluminum
T or F
At a PD fire when an engine back stretches the members should consider dropping two hand lines.
True
At a PD fire where is the hoseline:
A- flaked out
B- charged
C- bled
All are done outside the building
At a cellar fire in a PD, where does the 1st line get stretched?
To the entrance that will allow for quickest access to the fire
Which of the following are indications of a possible cellar fire in a PD?
1-smoke pushing from a chimney
2- Hot floorboards
3-smoke from attic windows or Louvered vents
4-smoke or fire venting from cellar windows
5-high heat and heavy smoke on first floor with no fire
All are signs of cellar fire in a PD
The books say only the IC can order the use of an exterior hoseline to be operated into the window at a cellar fire. You are the only company on scene at a cellar fire in a PD. Can you have the members operate the hoseline into a cellar window?
Yes, the IC can be the company officer until a chief arrives
A hoseline should not be operated into the cellar window at a fire in PD when members are operating in the cellar, are there any exceptions to this rule?
Yes, when members are trapped by fire
There is a fire in a cellar of a pd, there is an interior staircase leading to the cellar and there is an exterior entrance with bilco doors. Does it matter which you use for access if your stretching the 1st hoseline?
Yes, bilco doors are the least desirable way into a cellar and should only be used if they are the only access point.
At a pd fire, who can make the decision to reposition the 1st hoseline to a secondary entrance? 1-engine officer 2-truck officer 3- chief 4- acting batt chief
Only a chief or acting batt chief can make that call
Which of the following happen when the 1st hoseline is going to be repositioned at a fire in a PD?
1-an urgent message is given
2- the truck on the floor with the hose gets withdrawn
Both will happen before the hose is pulled out
At a fire in a PD, initially where does the 2nd hoseline get positioned?
Initially charged and positioned Outside
When pd is fully involved, what size hoseline should you consider stretching?
2 1/2”