Driver Engineer Guidebook Flashcards

1
Q

There are three factors that affect friction loss. They are:

A
  • The diameter of the hose
  • The volume of water flowing expressed in gpm
  • The length of the hose lay
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

_______ is the pressure at a specific pump discharge.

A

Discharge pressure (DP)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The use of a single hose line, typically 2 1/2”, 4-inch, or 5-inch, to supply two smaller attack lines is referred to as a ______ evolution.

A

wyed line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Connect the appropriate adapter ( ____” FEC or _____” NST)

A

4” FEC or 4 1/2” NST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Remove the steamer cap of the hydrant, open hydrant until a clear, solid stream is produced; flow for ___ - ___ seconds and then close the hydrant.

A

5 - 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When spotting apparatus with hydrant on the driver’s side you will need _____ feet.

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When spotting apparatus with hydrant on the officer’s side you will need ____ feet.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

In sprinkler and standpipe fire protection systems, the vertical pipes that carry water to the upper floors are called _____ and are usually _____ inches or more in diameter.

A

risers , 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Friction loss should be accounted for if the pipe diameter is less than ____ inches.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The most common pumping situations for multi-story buildings for this department are:

A
  • Through lines laid up stairs taking into consideration exiting and movement of suppresion forces.
  • Through a line or lines suspended on the outside of a building
  • To a sprinkler system
  • To a standpipe/sprinkler system
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

T or F: It should be noted that elevation means above or below a given point.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

As it relates to hydraulic calculations, the _______ refers to the midline of the pump.

A

elevation point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

There should never be less than _____ 2 1/2 inch lines supplying a sprinkler system FDC.

A

two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Suspended Line Ops: The line should be secured at the ____ floor, the ____ floor and every ____ floor between the top and bottom.

A

first, fire, third

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Suspended Line Ops: There should never be more than ___ floors between secured points.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The pump operator should maintain ____ psi to the sprinkler system FDC.

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the fire continues to progress, pertaining to a sprinkler system FDC, increase the DP to _____ psi maximum, by _____ psi increments.

A

200 , 25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

______ systems are the main source of water supply for fighting fires in high-rise or large buildings.

A

Standpipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Class I :

A

2 1/2 inch oulets for fire department use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Class II :

A

1 1/2 inch hose outlets for occupant use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Class III :

A

Combination standpipe, incorporates both Class I and Class II into a single system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

In most cases, buildings that are _____ stories, or ____ feet and above, have standpipe systems.

A

five, fifty

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Buildings of less than ____ stories may have dry systems, if they have any at all.

A

five

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

All new buildings that are ___ stories or more in height, except for open air parking structures that are a minimum of 20 feet from other structures, shall be fire sprinkler protected.

A

three

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Manual standpipes are usually found in buildings less than ___ feet in height.

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Standpipe systems in taller buildings are automatic ______ systems, which means they have a constant water supply.

A

wet standpipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

The vertical pipe that carries water to the upper floors is called a ____ and is from ___ to ___ inches in diameter and no allowance for FL is necessary.

A

riser, 4 to 6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Remember, it is mandatory that a minimum of ____ 2 1/2 inch lines are used to supply standpipe or sprinkler systems.

A

two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Maximum discharge pressure for 2 1/2 inch hose is _____ psi whereas maximum discharge pressure for LDH is ____ psi.

A

350 , 185

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

The friction loss of the standpipe system itself; generally accepted to be ____ psi.

A

25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

_____ apparatus should be given priority for positioning at building fires.

A

Aerial

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Consider spotting the apparatus on the corner of the building allowing access to ____ sides.

A

two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

Aerial Rescue: Remove victims in the following priority:

A
  1. Most severely threatened by current conditions.
  2. Largest number of groups of people.
  3. Remainder of people in the fire area.
  4. People in exposed areas.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Aerial Operations: If possible, spot the truck ___ feet from the building.

A

30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

The best spot, for advancing the pre-connected hand-lines is _______.

A

in line with the avenue of entry.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

Aerial Ladder Order of Movement/Operation:

A
  1. Elevate
  2. Rotate
  3. Extend
  4. Lower
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Relay pumping is used to overcome FL in supply hose and is based on three factors:

A
  • The diameter of the hose
  • The amount of water required
  • The distance from the water source to the attack pumper.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

The maximum speed for laying supply line is ____ MPH.

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Maximum PSI for 4” LDH is _____ psi.

A

185

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

Remember that the FL in the 4” supply line is 20 psi/100’ @ ______ gpm.

A

1000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

While operating apparatus equipped with a pressure governor, the attack pumper should be set to the ______ mode, while all others in the relay should be set to _____ mode.

A

PRESSURE , RPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

Attack pumpers, PDP is determined by ______.

A

fire attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

Most frequently, drafting operations are done only for the _______.

A

Underwriter’s Service Test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

A drafting operation is best done by a crew of _____ or more.

A

four

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

If the priming device does not discharge water within _____ seconds (1500 GPM pump), perform trouble shooting procedures.

A

45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

70 percent of its rated capacity at ____ ft. of lift and 60 percent at ____ ft.

A

15 , 20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
46
Q

For testing purposes, no more than ____ ft. of lift through _____ ft. of hose.

A

10 , 20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
47
Q

For best results, allow ____ feet of water on all sides of the strainer.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
48
Q

Pressure governor should be kept in the _____ mode until a successful draft is obtained.

A

RPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
49
Q

For drafting operation, increase throttle between ____ and _____ rpm.

A

1000 , 1200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
50
Q

Prime should be obtained between ____ to ____ seconds.

A

10 to 15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
51
Q

Drafting Operations: Before opening any discharges, increase throttle and maintain ____ to _____ psi on master discharge gauge.

A

50 to 100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
52
Q

A high reading on the vacuum side of the compound gauge with no water entering the pump within the proper time indicates that the suction lift is too ____ or the strainer is obstructed.

A

high

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
53
Q

AFFF is used at ___% or ____% to extinguish hydrocarbon fires, and ___% for polar-solvent (water-miscible) fires and oxygenated fuel blends.

A

1 , 3 , 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
54
Q
Application Rates for AFFF:
Class A - Wetting  \_\_\_\_\_\_%
Hydrocarbons       \_\_\_\_\_\_%
Ethanol                 \_\_\_\_\_\_%
Super Suppression \_\_\_\_\_%
A

1/2%
1%
3%
6%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
55
Q

The trailer (Foam 2) carries two _____ gallon totes of concentrate.

A

275

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
56
Q

IN-LINE Eductor : cam lock fitting

A

cam lock fitting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
57
Q

Place foam eductor no more than ____ feet form the nozzle.

A

200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
58
Q

IN-LINE EDUCTOR: Slowly increase pump discharge pressure to ____ psi.

A

200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
59
Q

Using clean water, flush all hoses, educators, and equipment used for product application for a MINIMUM OF ______ MINUTES.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
60
Q

Prior to flushing for foam clean-up, ensure that the eductor hose is _______ from the cam fitting on pump panel to avoid over pressurizing foam equipment.

A

disconnected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
61
Q

The Elkhart Built-In, By-Pass Eductor System, Model 240-125P is found on _____, ______, & ______ and is rated for _____ gpm flow.

A

FDP001, FDP005-007, & FDA050

125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
62
Q

Elkhart System: Slowly increase pump discharge pressure to ____ psi.

A

200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
63
Q

For Shut-Down Procedures for foam ops be sure to open the _____ and 1 3/4 inch handline and flow water of a minimum of 2 minutes.

A

Foam System Drain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
64
Q

Elkhart Eductors: These eductors are designed to achieve rated flow with an inlet pressure of _____ psi.

A

200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
65
Q

The Foam Pro 2000 system is found on _____ & _____ (these pumpers now use external in-line foam eductors).

A

FDP 008 & FDP009

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
66
Q

T or F : It is not necessary to pump at 200 psi for The Foam Pro 2000.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
67
Q

T or F : Unlike the apparatus equipped with the Elkhart Built-In, By-Pass Eductor system, more than one discharge can be used for operation with The Foam Proportional 2000.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
68
Q

Spot the foam trailer less than ____ feet away from the driver’s side pump panel.

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
69
Q

A ____ is the preferred water supply for foam operations.

A

hydrant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
70
Q

Remove two seals from the bottom of _____ of the 275 gallon foam totes.

A

ONE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
71
Q

Note: No foam will be supplied until the ____ pin is pulled and the _____ ball valve is rotated.

A

orange , red

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
72
Q

T or F: The smaller, open end, of the T-fitting is to be used for supplying a Foam Eductor.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
73
Q

FoaMidget : Connect the _____ colored hose to a

2 1/2” discharge.

A

maroon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
74
Q

FoaMidget Ops : T or F : DO NOT open the Tank Fill valve.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
75
Q

Open the 2 1/2” discharge to supply the FoaMidget with _____ psi (maroon line).

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
76
Q

The FoaMidget is a _______ powered device that supplies foam concentrate to the 2 1/2” axillary intake of the pumping apparatus.

A

venturi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
77
Q

The FoaMidget WILL NOT WORK unless ____ psi is maintained.

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
78
Q

Test the brakes by making a sudden stop: the distance traveled my be as little as ____ feet.

A

ten

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
79
Q

Any air leak causing the warning buzzer or light to signal low air pressure on a vehicle that has been driven within the last ____ hours, must be reported to the fire department shop.

A

24

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
80
Q

The fluid levels should be checked while the engine is ____.

A

cold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
81
Q

A pressure gauge must be used weekly ( _____ for front line apparatus, ______ for reserve apparatus.

A

Mondays , Sundays

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
82
Q

T or F : All air pressure testing must be done on a cold tire.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
83
Q

The voltmeter should show ____ to _____ volts when the charging system is operating normally.

A

13 to 14.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
84
Q

The fuel should be maintained at not less than ____ of a tank.

A

3/4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
85
Q

UREA : System should be maintained at no less than ____ a tank.

A

half

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
86
Q

Urea tanks have a _____ gallon capacity.

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
87
Q

Drive belts must be checked for tightness: about ____ inch of play is correct.

A

1/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
88
Q

Gauges : Air ____ psi

A

90-120

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
89
Q

Gauges : Oil ____ psi at idle / _____ psi maximum.

A

10-20 , 45-75

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
90
Q

Gauges : Voltage _____ volts.

A

13-14.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
91
Q

Gauges : Amps ______ amps.

A

50-160

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
92
Q

Gauges : Engine Temp ______ diesel / ______ gasoline.

A

180-210 / 190-220

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
93
Q

Gauges : Transmission Temp _______

A

180-210

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
94
Q

T or F : All fluids added to the unit must be recorded, except water used to refill the booster tank.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
95
Q

Research has shown that an antilock brake system can decrease the chance of a vehicle accident by _____%

A

18

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
96
Q

T or F : A skidding wheel has less traction than a non-skidding wheel.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
97
Q

There are four main components to an ABS system:

A
  • Pump
  • Valves
  • Controller
  • Speed sensors
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
98
Q

The ABS System : In position one, the valve is _____.

A

open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
99
Q

The ABS System : In position two, the valve ____ the line.

A

blocks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
100
Q

T or F: The ABS System: In position three, the valve releases some of the pressure from the brake.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
101
Q

The ______ watches the speed sensors and controls the valves.

A

controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
102
Q

Some ABS systems can cycle up to _____ times per second.

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
103
Q

The Jake Brake uses ______ to slow the vehicle.

A

engine compression

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
104
Q

If engine does not start within ___ seconds after depressing the START button, release the START button and allow the starter motor to cool for a minimum of ____ seconds before attempting to start the engine again.

A

15 , 60

105
Q

Shut Down Procedures: Idle engine for ____ to ____ minutes.

A

3 to 5

106
Q

The cab of the pumpers will be raised each ____ for in-service units and on each _____ for reserve units.

A

Monday , Sunday

107
Q

Lowering Cab: Continue to hold the Lower button for ____ seconds after the cab comes to rest on the frame to engage the Cab Locks.

A

5

108
Q

Pierce Manual Cab Lowering: Person 2 - locate the ____ knob ( ____ on FDP008, 009, & FDP050), underneath and to the front of the battery box on the officer’s side.

A

red, blue

109
Q

Sutphen Manual Cab Lowering: T or F: Person 2 - locates the pressure release valve, underneath the driver side front bumper.

A

True

110
Q

Pierce 75’ Aerial, FDA050: Aerial Set-up: Make sure the pump is _____, apparatus is stopped, the parking brake is set and transmission is in ____.

A

disengaged , neutral

111
Q

FDA050 : Set the wheel chocks behind and in front of the OFFICER SIDE FRONT wheel, sparing about ___ inches to prevent them from becoming stuck if the truck lowers onto them.

A

2

112
Q

Aerial Set-up: Make sure truck in is ____ idle.

A

low

113
Q

FDA050: Note the bubble level under the left rear compartment and operate the _____ side of the truck first.

A

low

114
Q

FDA050: Extend the stabilizers fully and lower them until about ____ inches off of the ground.

A

6

115
Q

FDA050: The ground where the truck is set-up must be capable of supporting ____ psi under each stabilizer.

A

75

116
Q

FDA050: Operate the LOW side stabilizer until about ___ degrees past level.

A

2

117
Q

FDA050: Slope more than ____ degrees or grade more than ____ degrees requires ladder repositioning.

A

3.5 , 5.5

118
Q

FDA050: T or F: When the truck is short jacked, it is not possible to operate the aerial over the short jacked side (without using emergency controls.)

A

True

119
Q

FDA050: ______foot pedal must be depressed in order to activate ladder controls.

A

“Dead Man Switch”

120
Q

FDA050: T or F: The ladder tip has a load limit of 750 lbs regardless of whether the ladder waterway is charged or uncharged.

A

True

121
Q

FDA050: The aerial is to be used in an _______ mode.

A

UNSUPPORTED

122
Q

Never set the ladder tip on roofs or ledges due to the negative load placed on the aerial.

A

True

123
Q

A standard firefighter weighs ____ lbs.

A

250

124
Q

FDA050: There is a hoist bar located in compartment # _____.

A

3

125
Q

FDA050: T or F: This truck has NO SAFETY FEATURES that will prevent the ladder form contacting and/or crushing the cab or other parts of the truck.

A

True

126
Q

FDA050: Emergency Hydraulic Power: To activate, the ____, _____, and ______ must all be ON.

A

battery, ignition, aerial master

127
Q

FDA050: T or F: Truck dose NOT automatically engage high idle like other ladder trucks.

A

True

128
Q

FDA050: Pinnable Waterway: Aerial Nozzle can be adjusted for placement at the ____ section or at the _____ of the ladder.

A

fly , middle

129
Q

FDA050: To operate the pinnable waterway, the aerial must be ______.

A

fully retracted

130
Q

FDA050: Bedding: Aerial must be fully _______ to be put in the boom support.

A

retracted

131
Q

FDA050: Once the aerial is lowered into the boom support, operate the lowering control function for approximately _____ more seconds to make sure the aerial will be secure during road travel.

A

five

132
Q

FDA050: To prevent overheating of the Emergency Pump Unit (EPU), limit it to a _____ minute run time with a _____ minute cool down period.

A

30 , 30

133
Q

FDA050: The Aerial Discharge Wheel Valve is a _____ inch valve and piping.

A

5

134
Q

FDA050: When another pumper/engine is to be supplying water to the aerial, this valve must be ______ to keep water from trying to enter the discharge side of the pump.

A

closed

135
Q

FDA050: Retraction should be done slowly when flowing ____ to _____ gpm and ladder should not be retracted if flowing _____ gpm or more.

A

50 to 1000 , 1000

136
Q

FDA050: The rear intake is used only to supply the aerial waterway.

A

True

137
Q

FDA050: The rear intake must only be supplied from a _____ source (engine/pumper), NEVER directly from a hydrant.

A

pressurized

138
Q

FDA050: Station setting for the Aerial Main Drain is ______.

A

CLOSED

139
Q

FDA050: Waterway Relief Valve is located at the rear. It is set to drip at _____ psi and drain at _____ psi.

A

220 , 250

140
Q

FDA050: Pump Panel Drains are _____ inch piping.

A

3/4

141
Q

FDA050: Generator: PTO driven and can be engaged anytime, even while driving.

A

True

142
Q

FDA050: Gauge should be watched to make sure the frequency and MHz do not exceed ____.

A

60

143
Q

If air pressure drops below ____ psi, the front wheel lock (brake) will engage.

A

60

144
Q

FDA051: Start-Up Procedures: Move the ignition switch down ___ positions to activate.

A

2

145
Q

FDA051: Set the wheel chocks behind and in front of the DRIVER SIDE REAR wheel, sparring about ____ inches to prevent them from getting stuck if the truck lowered onto them.

A

2

146
Q

FDA051: Extend the stabilizers fully and lower them until about ____ inches off the ground.

A

6

147
Q

FDA051: Before anyone can climb the ladder, three safety checks must be confirmed:

A
  1. One operator must be stationed at the ladder controls.
  2. Personnel climbing the ladder must be wearing a ladder belt.
  3. Ladder rungs must be aligned.
148
Q

FDA051: The aerial has a load limit of _____ lbs if the ladder pipe is dry. If it is charged, the load is cut to ____ lbs.

A

1000 , 750

149
Q

FDA051: The aerial is to be used in an _______ mode.

A

UNSUPPORTED

150
Q

FDA051 is not equipped with tip controls.

A

True

151
Q

FDA051: Aerial must only be raised while in the ____ support.

A

boom

152
Q

FDA051: High idle maintains _____ RPM’s.

A

1000

153
Q

Rungs should always be aligned when someone is preparing to climb the ladder.

A

True

154
Q

FDA051: Be sure to activate the ______ and remove safety pins prior to raising the stabilizers.

A

Jack Release

155
Q

FDA051: To prevent overheating of the EPU, limit it to a ____ minute run time.

A

10

156
Q

EPU will not shut down automatically.

A

True

157
Q

FDA051: Aerial waterway is heavy duty aluminum tubing. Lower sections are ____ inch piping expanding to ___ inch at the fourth section (tip).

A

3 1/2 , 5

158
Q

FDA051: Retraction should be done slowly when flowing ____ to ____ gpm and ladder should not be retracted if flowing _____ gpm or more.

A

500 to 1000 , 1000

159
Q

FDA051: Waterway Drain should always be opened after aerial waterway use, ____ retracting the ladder.

A

before

160
Q

FDA051: Primer is air activated.

A

True

161
Q

FDA051: DPF (Diesel Particulate Filter)

A

True

162
Q

FDA051: The regeneration will take approximately ___ to ___ minutes.

A

20 to 40

163
Q

FDA051: Cab must be lifted to check power steering fluid and coolant.

A

True

164
Q

FDA051: ALWAYS open the door of the generator compartment when generator is in use to prevent overeating.

A

True

165
Q

FDA052: Aerial Set-Up: DO NOT engage PTO when rpm are above _____.

A

1100

166
Q

FDA052: Set wheel chocks on driver side ______ rear wheel.

A

FORWARD

167
Q

FDA052: Lower both riggers until approximately ___ to ____ inches off the ground.

A

6-8

168
Q

FDA052: Deploy low-side stabilizer to approximately ____ degrees past center.

A

2

169
Q

FDA052: Aerial Set-Up: The front tires should be ____ inch off the ground.

A

1/2

170
Q

FDA052: Slope more than ____ degrees or grade more than ____ degrees requires ladder repositioning.

A

5 , 20

171
Q

FDA052: It is recommended to turn the UPPER POWER switch ____ during climbing or while exiting the platform to prevent accidental operation of the boom.

A

off

172
Q

FDA052: Alarm will sound when rotating aerial until ladder clears ___ degrees over the rear of apparatus and ___ degrees over the cab section.

A

10 , 20

173
Q

FDA052: To operate the aerial at all while short jacked, the ________ button must be pressed simultaneously at the aerial control panel and turntable while raising the aerial out of the bed.

A

INTERLOCK OVERRIDE

174
Q

Before anyone can climb the ladder, three safety checks must be confirmed:

A
  1. One operator must be stationed at the turntable.
  2. Personnel climbing the ladder must be wearing a ladder belt.
  3. Ladder rungs must be aligned
175
Q

FDA052: The ladder tip has a load limit of _____ lbs uncharged and _____ charged.

A

1000, 500

176
Q

FDA052: The stokes has a capacity of ____ lbs per pair.

A

400

177
Q

FDA052: Max of ____ lbs in platform when using stokes arms.

A

500

178
Q

FDA052: Rescue lifting shackle has a ____ lbs max.

A

800

179
Q

FDA052: On-Board Breathing Air: K tank with ____ psi. Station setting for the regulator is ___ psi.

A

4500 , 70

180
Q

FDA052: Fill attachment to On-Board Air: First low air alarms at ____ psi. Second low air alarms at ___ psi.

A

900 , 300

181
Q

FDA052: Auxiliary Hydraulic Pump: To activate, the ignition and ______ must all be ON.

A

Ladder/jack PTO

182
Q

FDA052: Turntable controls override platform controls.

A

True

183
Q

FDA052: Water system is rated for up to ______ gpm’s.

A

2000

184
Q

FDA052: The water curtain disperses at ____ gpm.

A

75

185
Q

FDA052: Aerial must be fully _____ to be put in the boom support.

A

retracted

186
Q

FDA052: Operation of the Auxillary Hydraulic Motor should not exceed ____ minutes without allowing ___ minutes to cool.

A

2 , 5

187
Q

FDA052: HIGH IDLE will not engage while pump is i gear.

A

True

188
Q

FDA052: Retraction should be done slowly when flowing ___ to ___ gpm and ladder should not be retracted if flowing ____ gpm or more.

A

500 to 1000, 1000

189
Q

FDA052: Aerial Main Drain: It is ___ inch piping and should always be opened AFTER aerial waterway use, before retracting the ladder.

A

2

190
Q

FDA052: Station setting for Aerial Main Drain is _____.

A

OPEN

191
Q

FDA052: Primer is ____ actuated.

A

air

192
Q

FDA052: Pump Panel Drains are ____ inch piping.

A

3/4

193
Q

FDA052: Gauge should be watched to make sure the frequency and MHz do not exceed ____.

A

60

194
Q

FDA052: Once the generator reaches ____ degrees Farenheit, it shuts down.

A

180

195
Q

FDA052: The cord reels are each ____ feet long and provide 120v.

A

200

196
Q

FDA052: To cancel a parked regeneration, hold the DPF switch to the ON position for ____ seconds and release.

A

5

197
Q

FDT:017 Do not depress the accelerator prior to starting!

A

True

198
Q

FDT017: If the engine does not start within ___ seconds, release the key - wait ___ seconds - and try again.

A

5 , 10

199
Q

FDT017: If the engine does not start after ____ attempts, turn off the key and wait approximately ___ minutes.

A

two, 2

200
Q

FDT017: Starting the Pump Engine: If the engine does not start within ____ seconds, release the starter and wait ___ seconds before trying again.

A

15 , 60

201
Q

FDT017: Foam Operations: Maximum operation pressure is ____ psi.

A

500

202
Q

FDT017: Turn the _____ to the Foam position.

A

selector valve

203
Q

FDT017: Refill Operations Foam: Turn the Percentage Selector Valve to ___.

A

1.0

204
Q

FDT017: Refill Operations Foam: The refill operation should take approximately ___ minutes.

A

2

205
Q

FDT017: The winch on this vehicle is electrically operated and requires NO shifting of gears inside the cab.

A

True

206
Q

FDT017: Disengage 4-Wheel Drive: Place the truck transmission in REVERSE and back the truck up a minimum of ___ feet. You must manually unlock the hubs.

A

10

207
Q

At start-up, pump _____ psi unless otherwise directed by the source pumped operator.

A

100

208
Q

FDT017: Use ____ - wheel drive when driving on paved or extremely hard surfaces.

A

2

209
Q

FDA050: Max wind speed Go/No Go:

A

35 mph

210
Q

FDA051: Max wind speed Go/No Go:

A

Sustained 35 mph, Gusts of 50 mph

211
Q

FDA052: Max wind speed Go/No Go:

A

Sustained 35 mph, Gusts of 50 mph

212
Q

FPD001, FDP005-FDP007: Gross Vehicle Weight:

A

42,740 lbs

213
Q

FDP001, FDP005-FDP007: Overall Length:

A

30 feet

214
Q

FDP001, FDP005-FDP007: Overall Width:

A

8 feet

215
Q

FDP001, FDP005-FDP007: Road Clearance Height:

A

10 ft 5 in

216
Q

FDP001, FDP005-FDP007: ___ feet of 4-inch LDH

A

1000

217
Q

FDP001, FDP005-FDP007: ____ feet of 2 1/2 inch

A

500

218
Q

FDP001, FDP005-FDP007: Wheelbase:

A

184.5 inches

219
Q

FDP001, FDP005-FDP007: Pump Type:

A

Hale, 1500 gpm Single Stage

220
Q

FDP001, FDP005-FDP007: Engine:

A

Detroit Diesel 60 Series, 430 hp

221
Q

FDP001, FDP005-FDP007: Manual Pump Engagement:

A

NONE

222
Q

FDP001, FDP005-FDP007: Auxiliary Brake:

A

Jake Brake

223
Q

FDP008-FDP009: Engine:

A

Detroit Diesel 60 Series, 455 hp

224
Q

FDP008-FDP009: Manual Pump Engagement:

A

Compartment #1, bottom left-hand corner

225
Q

FDP008-FDP009: Groos Vehicle Weight:

A

50,500 lbs

226
Q

FDP008-FDP009: Overall Length:

A

31 feet

227
Q

FDP008-FDP009: Overall Width:

A

8 ft 2 in

228
Q

FDP008-FDP009: Wheelbase:

A

173.5 inches

229
Q

FDP10-FDP13: Engine:

A

Cummins ISL, 450 hp

230
Q

FDP10-FDP13: Booster Tank Capacity:

A

750 gallons

231
Q

FDP10-FDP13: Gross Vehicle Weight:

A

42,000 lbs

232
Q

FDP10-FDP13: Overall Length:

A

33 feet

233
Q

FDP10-FDP13: Overall Width:

A

10 ft 9 inches

234
Q

FDP10-FDP13: Wheelbase:

A

196 inches

235
Q

FDP10-FDP13: Road Clearance Height:

A

10 feet 2 inches

236
Q

FDP10-FDP13: 2 dead loads of _____ ft 2 1/2’

A

300

237
Q

FDA50: Ladder Height:

A

75’ ft

238
Q

FDA50: Horsepower:

A

515

239
Q

FDA50: Booster Tank Capacity:

A

475 gallons

240
Q

FDA050: Gross Vehicle Weight:

A

53,800 lbs

241
Q

FDA050: Overall Length:

A

36 ft 4 in

242
Q

FDA050 Overall Width:

A

8 ft 6 in

243
Q

FDA050: Width of Outriggers Fully Extended:

A

17 ft 3 in

244
Q

FDA050 has 1,000 ft of 4 INCH LDH!!

A

True

245
Q

FDA051: Horsepower:

A

515

246
Q

FDA051: Booster Tank Capacity:

A

470 gallons

247
Q

FDA051: Gross Vehicle Weight:

A

54,000 lbs

248
Q

FDA051: Overall Length:

A

40 feet 5 inches

249
Q

FDA051: Overall Width:

A

8 ft 2 in

250
Q

FDA051 Wheelbase:

A

232 inches

251
Q

FDA051: Road Clearance Height:

A

10 ft 10 in

252
Q

FDA051: Width of Outriggers Fully Extended:

A

16 feet

253
Q

FDA051: ___ feet of 2 1/2’ hose

A

500

254
Q

Winch Operations: Insert the plug end from the remote control into the receptacle on the ____ side of the winch.

A

left

256
Q

Winch Operations: Once operations are complete, return the clutch lever to the ___ position, rewind the excess cable and secure the hook.

A

OUT

257
Q

The tool box on Foam 2 contains a Hydro-Foam ___ gpm fog nozzle.

A

350

258
Q

The tool box on Foam 2 contains a Blitz Fire Ground Oscillating Master Stream with a __ inch Aspirating Tip.

A

2”

259
Q

The tool box on Foam 2 contains ___ 1 1/2” fog nozzles with foam tubes attached.

A

2

260
Q

Truck should be in an area clear of all trees, buildings, vehicles and people during regen due to the very high exhaust temperatures (_____ degrees or more.)

A

1200