Chapter 8 Flashcards

1
Q

Heavy timber is categorized as type ___.

A

Type IV/4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Wood columns, sawn or glued laminated, supporting floor loads, no less than ___ in any dimmension.

A

8”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Wood columns, sawn or glued laminated, supporting only roof loads, no less than ___ in width and ___ in depth.

A

6” width and 8” depth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Wood beam and girders, sawn or glued laminated, supporting floor loads only, no less than ___ in width and ___ in depth.

A

6” width and 10” depth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Wood beams and girders, sawn or glued laminated, supporting roof loads only, no less than ___ in width and ___ in depth.

A

4” width and 6” depth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Framed or glued laminated arches(grade to floor line) and timber trusses that support floor loads, no less than ___ in width or depth.

A

8”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Framed or glued laminated arches(grade to floor line) that do not support floor loads, no less than ___ in width and ___ depth, for lower half of members height and not less than ___ in depth for the upper half of the members height.

A

6” width
8” depth
6” depth top half

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Framed and glued laminated arches for roofs that spring from the top of walls/abutments and timber trusses that do not support floor loads, no less than ___ in width and ___ in depth.

A

4” width and 6” depth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Yard hydrants are hydrants with ___ outlets and no ___ connection that were intended for use by industrial fire brigades.

A

2 1/2” outlets

pumper connection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly