Chapter 12 Relay Pumping Ops Flashcards

1
Q

A relay pumping operation consists of:

A

A pumper positioned at the water supply pumping and pressurizing water through a supply to another pumper that repressurises and so on until it reaches the attack pumper

Pg 425

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In oder to be effective relay operations require:

A

Preplanning, training, and coordinating of all participants

Pg 425

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Water supply pumper in relay pumping:

A

Should have the largest pumping capacity. This pumper takes water from the hydrant or static source and pumps it to the next relay pumper.
Pg 426

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Relay pumper:

A

Receives water from another pumper, raises the pressure and supplies it to the next apparatus

Pg 427

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fire attack pumper:

A

Pumping apparatus located at the fire scene that receives water from the relay and is responsible for supplying the attack lines and appliances required for suppression

Pg 427

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Basically the need for relay pumping is determined by the:

A

Amount of water required at an incident and the distance between the incident scene and the water source

Pg 427

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If flow through a relay needs to be increased it can be done in 3 ways:

A

Increase the diameter of the supply hose or add more supply lines
Increase the pump discharge pressure
Add more pumpers to the relay to overcome friction loss or elevation loss

Pg 428

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Increasing flow during a relay operation may e accomplished by:

A

Placing additional pumpers in the system

Pg 428

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The overall capacity of a relay system is determined bye the:

A

Smallest pump and the smallest diameter of hose used in the relay

Pg 432

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When laying long distances the hose lay between each pumper should be:

A

As equalized as possible

Pg 432

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

It is advisable or a driver to maintain an intake pressure of ____ to _____ psi as a relay pumper

A

20/30

Pg 433

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Once the relay operation is flowing water at the desired pressure the driver of the attack pumper should:

A

Set the pressure governor at an appropriate level

Pg 433

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Apparatus equipped with pressure governors should be set in the_______ mode when acting as the attack pumper and in the________ mode while working as a relay pumper

A

Pressure
Rpm

Pg 433

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When the need for relay pumping has ended the operations should be discontinued from the:

A

Fire scene first

Pg 434

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Open relay method consists of:

A

Deploying portable folding drop tanks at each intake for pumpers in the relay operation

Pg 435

How well did you know this?
1
Not at all
2
3
4
5
Perfectly