AVIONICS VENTILATION Flashcards

1
Q

BLOWER FAULT

A
  • low blower pressure
  • duct overheat
  • computer failure
  • avionics smoke
  • an external horn will sound
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

EXTRACT FAULT

A
  • low extract pressure
  • computer failure
  • avionics smoke
  • an external horn will sound
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Open Circuit Configuration

A
  • both inlet and outlet flaps are fully open
  • on the ground with warm ambient conditions
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Closed Circuit Configuration

A
  • both inlet and outlet flaps are fully closed
  • Skin Exchange Inlet Bypass Valves are open
  • on the ground with cool ambient conditions
  • also normal inflight, from TO power to landing
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Intermediate Circuit Configuration

A
  • inlet flap closed with the outlet small flap open
  • this is inflight from the application of TO power in extremely warm ambient conditions
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What would cause the GEN 1 LINE SMOKE light to illuminate?

A

Smoke in the avionics ventilation ducting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

With the GEN 1 LINE SMOKE light, what other indications of avionics smoke are there?

A

ECAM warning and amber FAULT lights in the EXTRACT and BLOWER pushbuttons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly