What computers monitor and control the pneumatic system?
2 Bleed Monitoring Computers (BMC)
If one BMC fails, can the other take over?
Yes
The PACK FLOW selector has LO, NORM, and HI positions. What is the rule of thumb for setting?
LO: Occupants below 138
HI: For abnormally hot and humid conditions
NORM: For all other operating cases
What modulates the trim air valves?
The zone regulator adjusts the trim air valves and pack outlet temps to optimize the zone temps
How are the Pack Control Valves controlled and regulated?
Pneumatically operates and electrically controlled by the pack controller
What is the purpose of the Emergency Ram Air Inlet?
- cabin ventilation in case both packs are inop
- clear smoke out of the cabin
What happens when the RAM AIR pb is selected to ON?
- ram air valve opens, and
- outflow valve will fully open when cabin differential pressure is less than 1 psi (as long as the cabin MODE SEL pb is in AUTO)
- the emergency ram air inlet and outflow valve will not open if ditching has been selected
What do the Pack Flow Control Valves do?
- regulate amount of bleed air supplied to the packs
- function as shut off valves
When will a Pack Flow Control Valve automatically close?
- during engine start
- upstream pressure below min
- pack overheat
- pressing an ENG FIRE pb
- ditching pb selected ON
What does the the Hot Air Valve do?
Controls supply of hot bleed air to all 3 Trim Air Valves
What do the Trim Air Valves do?
Add hot air to airflow from mixing unit to maintain selected zone temperatures
How are the Trim Air Valves controlled?
Electrically by the zone controller
What happens if the primary channel of the Zone Controller fails?
- Hot Air valves close
- Trim Air valves close
- Lose flow function
- Lose optimized temperature
What would cause an amber PACK FAULT light to illuminate?
- Pack overheat
- Switch position disagreement with pack FCV
What does the amber FAULT light in the APU BLEED pb indicate?
Bleed leak
What causes the amber FAULT light on the ENG BLEED pb?
LOOSA
- Leak
- Overpressure downstream
- Overheat
- Starting engine and valve not closed
- APU bleed on and valve not closed
What happens if both the primary and secondary channels of the Zone Controller fail?
- optimized and back-up temp regulation is lost
- Pack 1 delivers a fixed temp of 68* F
- Pack 2 delivers a fixed temp of 50* F
What logic controls the X-BLEED valve when the X-BLEED switch is in AUTO?
- When APU BLEED valve is OPEN, the X-BLEED valve is open
- When the APU BLEED valve is CLOSED, the X-BLEED valve is closed
What is the function of the HOT AIR pb?
- The HOT AIR valve controls the supply of the hot air to all of the trim air valves which maintain the selected temperature in each zone
- Valve position is controlled by the HOT AIR pb. The valve automatically closes in the event of a fault