(2025 EXAM) Man 10 DIV AND HYPERB SYS CERT Flashcards
chap 2,3. Appendix A,C
- Who can close out a CWP?
-Diving Officer/SDS
Who can approve temporary alternative system alignment with adequate tag-out procedure while the rec remains open?
CO or designated rep
How do you document rework in the REC log?
place a - after the original rec number ex.24-001-1
How often do you audit rec logs?
Quarterly
O2% greater than what % requires O2 worker qualification?
25%
Valve seat tightness time and pressure?
30 minutes plus time to inspect at MOP
Hydrostatic/pnuemo test?
1.5 times MOP. No leakage allowed
System Drop Test all requirements?
->1000psi air 24 hours, 1% of initial pressure
-<1000psi air 6 hours, 5% of initial pressure
-Helium/HEOX 24 hours, 1% of initial pressure
-O2 24 hours, 0 allowable drop
What is all rope required to have?
Certificate of break
Service life of wire rope?
5 years
Static test for DHS?
200% for 10 minutes
Dynamic Test?
150% run through 3 complete cycles of operation
What do you do with rope that has exceeded 75% of its minimum breaking strength?
Discard
Replacement criteria for Wire rope?
6 broken wire in one rope lay length, or three broken wires in one strand lay length
Category 1A card?
Corrective action must be accomplished prior to manned use of the system. Results in termination or suspension of existing certification.