(2024 Exam) MK-16 Flashcards
Ch 2, 3
Normal working limit for N2O2/HEO2?
Normal Working Limit 150 feet - N2O2 (79/21)
NormalWorkingLimit 300feet-HeO2 (88/12)
Inconel bottle FV? SCF @ 3000psi?
FV= .101
SCF @ 3000psi = 21 SCF
Absorbent duration decreases as ______ decreases and _____ increases?
Temperatures decrease
Depth increase
Breathing loop capacity in liters?
8.5 liters
Initial setup procedures are done when and at what interval?
Every six months/prior to Mission
Or
When a sensor is replaced or repositioned
PEA, center section, or secondary display is replaced
If bottles have been allowed to fall to 0 psi (or have been contaminated with a different gas), you must purge bottles a total of ____ times before final jam of 3000psi is accomplished.
3 times
Jamming to 300 psi then purging to 0 psi
A SCUBA Diver may be tended to a MK-16 diver/s with no additional witness float or tending line during training dives. Flip card 👇🏻
The SCUBA bubbles will suffice for marking or tracking the divers location.
This is to cut down on lines and decrease chances of entanglement.
Max descent rate?
60ft/min
Maximum allowable PPO2?
1.9 ata
How often should you check your secondary display?
Every 2 to 3 minutes
Pre-Dives are good for how long?
14 Days
LO-MU is recertification and hydrostatic testing is preformed at a minimum of every ___ years?
5 years
Navy safety precautions for forces afloat?
OPNAVINST 5100.19
Navy Safety Precautions for Shore Activities?
OPNAVINST 5100.23
The minimum discharge voltage of the primary battery is ___V(Modern) or ___V (Legacy). At which point it is considered unreliable and should be discarded.
Modern- 5.2V
Legacy- -.95