08 - Fire Protection Flashcards

1
Q

FIRE PROTECTION

  1. Which areas of the aircraft have fire extinguishing capability?
A
  • Engines
  • APU
  • Lower Cargo Compartments
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  1. What fire protection functions are available without battery power?
A

None

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  1. Can you discharge the fire bottles using only battery power?
A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  1. How is the fire warning bell silenced?
A

Pressing either Master FIRE WARN button or BELL CUTOUT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  1. How is an engine fire extinguished?
A

By pulling the respective Fire Switch and rotating it. This discharges one of two halon bottles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  1. Which systems are affected by pulling an engine fire switch and how are they affected?
A
  • Closes spar fuel shutoff and engine fuel shutoff valves
  • Bleed valve & pack valve closed
  • Trips the generator control relay & breaker
  • closes hydraulic shutoff valve
  • Arms one squib on each bottle
  • Allows the engine fire switch to be rotated
    -Reverser is disabled
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  1. How is a dual loop failure of an Engine Fire Detection System indicated?
A

An amber FAULT light on the Overheat/Fire Protection Panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  1. How many fire extinguishing bottles are provided for the APU?
A

One

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  1. Does the APU have automatic fire extinguishing?
A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  1. What happens when pulling the APU fire switch?
A

• provides a backup to the automatic shutdown feature
• closes the APU fuel shutoff valve
• closes the APU bleed air valve
• closes the APU air inlet door
• trips the APU generator control relay and breaker
• allows the APU fire switch to be rotated for discharge
• arms the APU fire extinguisher bottle squib

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  1. Where is the APU Fire Ground Control panel located?
A

Right main wheel well

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
  1. What does placing the fire detection TEST switch to FAULT/INOP test?
A

The systems ability to detect a fault or inop equipment within itself

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
  1. What does placing the fire detection TEST switch to OVHT/FIRE test?
A

The overheat and fire detection loops on both engines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
  1. What is indicated by the illumination of the DETECTOR FAULT light on the CARGO FIRE
    panel?
A

One or more detectors in the Lower Cargo Compartment Fire Detection System has failed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
  1. What fire protection and extinguishing equipment is available in the lower cargo compartments?
A

2 halon for suppression bottles, one HRD and one LRD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly