Who Does It Flashcards
Overall responsibility for complying with API 510 (4.1)
Owner/User
During Repairs and Alterations - Responsible for Quality Control (4.2.3)
Repair Organization
Assure owner - testing, inspection & examination activities meet Code (4.2.4)
Inspector
Evaluate and accept NDE examination results (4.2.4)
Inspector
Develop the Inspection Plan for Vessels & Relief Devices (5.1.1.1)
Inspector OR Engineer
Review the Inspection Plan for equipment operating at elevated temperature (5.1.1.1)
Corrosion Specialist
Choose to conduct RBI assessments (5.2)
Owner/User
Review prior vessel history prior to inspections (5.3.4)
Inspector
Familiar with characteristics of potential damage mechanisms (5.4.2)
Inspector
Perform Internal Inspection (5.5.2.1)
Inspector
Determine whether it’s necessary to remove deposits or lining (5.5.2.3)
Inspector AND Corrosion Specialist
Perform On-Stream Inspection (5.5.3.1)
Inspector OR Examiner
Approve On-Stream Inspection work performed by Examiners (5.5.3.1)
Inspector
Perform External Inspection (5.5.4.1.1)
Inspector OR Qualified Others
Take Thickness Measurements (5.5.5.1)
Inspector OR Examiner
Review corrosion data if short-term corrosion rate varies significantly (5.5.5.3)
Inspector AND Corrosion Specialist
Assure those taking thickness measurements are trained and qualified (5.5.5.4)
Owner/User
Determine locations of CMLs for vessels with localized corrosion (5.6.3.1)
Corrosion Specialist
Involve if the # of CML’s will be signigicantly reduced or eliminated (5.6.3.2)
Corrosion Specialist
Determine type of expected damage and select NDE method (5.7.1)
Inspector AND Engineer or Corrosion Specialist
Perform UT flaw detection for finding linear flaws (5.7.1.2)
QUTE - API Certified UT
Determines when a pressure test is needed after a repair - “believes” (5.8.1.1)
Inspector
Review use of a component pressure test in lieu of complete vessel hydro (5.8.1.2)
Engineer
Determine the test pressure for non-code related pressure tests (5.8.2.2)
Owner/User
Hydro of 300 SS, verify water quality and that vessel is drained and dried (5.8.4.2)
Inspector