Data Sheets - Time Intervals & Percentages Flashcards
NDE - Minimum time an examiner should be in a darkened area prior to using a black light for MT & PT exams (V: T-676.4.b & T-777.2.b)
5 minutes
NDE - Final interpretation of a PT exam after application of developer (time range) (V: T-676.1)
10 - 60 minutes
NDE - Minimum time to wait for checking for delayed cracking after repairs to SS cladding (510: 8.1.5.4.4)
24 hours
NDE - Maximum Calibrating Intercal - MT Permanent Magnet Yoke (V: T-762 (a))
Daily
NDE - Maximum Calibrating Interval - RT densitometer (V: T-262.1)
90 days
Welding - Maximum time that welder or welding operator maintains qualifications for a welding process without using that process (IX: QW-322.1.a)
6 months
NDE - Maximum calibrating interval - Electromagnetic MT Yoke (V: T-762 (a))
1 year
Inspecion - Maximum Interval - External Inspection (510: 6.4.1)
Lesser of 5 years or Internal Interval
Inspection - Maximum Interval for Relief Devices in fouling or corrosive service (510:6.6.2.2.a)
5 year
Inspection - Maximum Interval for Internal or On-Stream Inspection (510: 6.5.1.1)
Lesser of 10 years or 1/2 Life
Inspection - Maximum Interval for Relief Devices in non-fouling or non-corrosive service (510: 6.6.2.2.b)
10 years
RBI - Maximum Interval for the RBI Reassessment (510: 6.3.2)
10 years
Inspection - Minimum Remaining Life required when performing an On-Stream inspection in lieu of an Internal Inspection (510: 6.5.2.1.b.2)
10 years
NDE - Maximum Calibrating Interval - Check the light intensity of a black light used in a MT or PT exam (V: T-676.4(e) & T-777.2(e))
Before & After Use
RT Film Density - Limits of weld as compared to the IQI (range) (V: T-282.2.a)
-15 to +30 %