Maximum allowed corrosion rate when using On-Stream inspection in lieu of an Internal (in ipy) (510: 6.5.2.1.b.1)
0.005 ipy
Ratio of Endurance Limit Stress to Ultimate Tensile Stress for Carbon Steel (571: 4.2.16.3.b.ii)
0.4 - 0.5
Static Head Factor (psig per height of water in feet) (Body of Knowledge)
0.433 psig/ ft.
Design - Joint efficiency when using Full RT on a Type 1 joint (VIII: table UW-12)
1.0
FFS - Joint efficiency when evaluating corroded area away from a weld by greater of: 1” or 2t (510: 7.4.5)
1.0
NDE - The # of additional RTs required when a Spot RT has a defect (VIII: UW-52.d.2)
2
Weld Qualification - Number of tension tests to qualify a WPS (IX: QW-451.1)
2
Weld Qualification - Number of bend tests to qualify a welder or welding operator in welding positions 1G-4G (IX: QW-452.1.a)
2
NDE - Minimum # of exposures to RT 360 degrees of a weld using a double-wall technique, double-wall view (elliptical shot) (V: T-271.2.b.1)
2
NDE - RT film Density Range - allowed for the weld & IQI when using a gamma ray source (V: T-282.1)
2.0 - 4.0
NDE - Minimum # of exposures to RT 360 degrees of a weld using a double-wall technique, single-wall view (V:T-271.2.a)
3
Impact Test - Number of test bars required in each set of impact test specimens (VIII: UG-84.c.1)
3
NDE - When using a shim under a hole-type IQI, the number of sides of the IQI that must be seen in the RT image (V: T-277.3)
3
Design - Current Safety Factor of ASME Section VIII (510L 7.7.3)
3.5
Design - Pre-2000 Safety Factor of ASME Section VIII (No Reference)
4.0