Generally where will backdrafts occur inside of a structure
In proximity to the main body of fire
True or False. Regarding “Flow Path”, this can be a bidirectional or unidirectional flow dependent on the location of the main body of fire to vent openings
True
Give an example of a Bidirectional flow path
Fire is in a single compartmented room
Note: As fire grows using available oxygen, the neutral plane drops lower in the open doorway. Hot gases exhaust above neutral plane. Fresh air is pulled in below the neutral plane
Give an example of a Unidirectional flow path
A multi level compartment fire
Note: The neutral plane will be higher in this compartment. Fresh air pulls thru a doorway in 1 direction. Hot gases exhaust out of a vent point on the floor above in 1 direction
Name 2 actions members must take when encountering “rollover” conditions
- Open a hose line to cool the environment 2. Exit the fire area and control the door until the arrival of a line
Changes of ventilation profile indicators must be communicated to who
Ladder Co. Officer and IC
If an officer encounters high heat and heavy smoke without a charge line, what should he/she consider (2 answers)
- Immediately exit the fire area
2. Limit additional ventilation
Regarding safety teams, a known life hazard is defined as follows (3 definitions)
- Victim can be seen by a rescuer 2. Victim can be heard by a rescuer 3. Member has info from a credible source or person at the scene and indicates location of the life hazard
If smoke and fire are venting downward, horizontally or pulsing from an opening in the building will indicate what about fire conditions
Wind impacted
Fire and smoke should be venting in what 2 directions
Outwards and upwards
In addition to transmitting a 10-45 for a victim, name 2 other pertinent pieces of info that should be given to the officer or IC
- Location 2. Planned exit route
Name an occasion when limited ventilation of a fire apt. is justifiable if it facilitates search operations
When fire has not communicated to the floor above
True or False. The change in fire dynamics of modern content fires require that all ventilation be controlled, communicated and coordinated with operations on the fire floor
True
True or False. If vertical ventilation is delayed or withheld the bulkhead shall remained closed even to check for trapped occupants behind the door
False
Check for trapped occupants behind the door and then close it
Additional venting such as the skylight shall be done during what phase of the fire
After the main body of the fire has been extinguished