Places Of Worship Flashcards

1
Q

Ventilation openings provide an excellent location for water application to extinguish fire in what 2 areas?

A

Above the concealed Attic or Cockloft

Note: Vent Opening is typically located on the front or rear of the long side of a place of worship

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When the attic vent is at the front of a church, where will it be located in relation to the Rose window

A

A few feet above the Rose window

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Often located on exposures two and four, Clearstory windows will be located at approximately what height

A

Above eye level

Note: Clearstory walls rise above the roof lines of the lower isles where the windows are located.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

True or false: operating a tower ladder stream into a rose window will extinguish the fire at the upper reaches of the church

A

False

May extinguish fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Clearstory windows are often located on what exposure (s)

A

2 and 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Most fires in places of worship that are discovered and reported quickly will be extinguished with the use of how many handlines

A

1 or 2 handlines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

True or false: seating areas in churches are often large areas with movable seats

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

True or false: When fire involves a Place of worship in a Rowframe, Rowframe FF procedures shall apply

A

True

Note: places of worship can be found in brownstones, rowframes, or PD’s.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A Place of Worship that has pointed arches, tall designs, flying buttresses, vaulted ceiling‘s and large, open interior areas and built in the shape of a crucifix is indicative of what style of architecture

A

Gothic architecture

Note: all firefighters should be aware of this type of architecture and the inherent features

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

In newer architecture places of worship, name a feature that will not be found as opposed to older architecture

A

Hi vaulted ceiling‘s will not be found

Note: Both older and newer architecture places of worship are susceptible to early collapse

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Older style of churches are susceptible to early collapse due to what type of construction feature

A

Large high timber truss roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Newer style of churches are susceptible to early collapse due to what type of construction feature

A

Lightweight truss construction

Note: newer style may also have a bell tower, steeple or other features described within this bulletin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Name the five major defects or faults in the construction of places of worship

A
  1. Early collapse potential 2. Numerous concealed voids 3. A vast quantity of combustible material used in the truss roof construction 4. Lack of fire suppression and detection systems 5. Large open areas with limited or no fire stopping
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Since FF’s must gain access to the attic space to check for fire extension, what type of staircase may they encounter

A

Narrow spiral staircase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Old dried out lumber with an accumulation of (blank) will contribute to the fire load

A

Candle wax buildup

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A decision to employ TL streams that were positioned early on as part of the incident strategy will be implemented when fire reaches where

A

Upper inaccessible areas of a place of worship

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Name three additional hazards that can be found in Places of Worship

A
  1. Exterior insulation finishing systems (EIFS)
  2. Cell sites
  3. Fire escapes
18
Q

Cellar fires located in Places of Worship may extend how to the upper floors

A

Hidden voids

19
Q

Choir Lofts are often located where

A

Directly above the main entrance and below the large rose window

Note: It is common for the pipes from an organ to partially block part of the Rose window affecting stream application into the Rose window

20
Q

High vaulted ceiling‘s can be (blank) or more ft. in height

A

60

Note: This height will require a 2 1/2 hose to adequately reach the ceiling and apply water

21
Q

Name six collapse dangers that are found in Places of Worship

A
  1. Bell tower
  2. Minaret
  3. Steeple
  4. Ceilings
  5. Sidewalls
  6. Roof
22
Q

True or false: There may be a steeple found above a bell tower

A

True

23
Q

What exposure or exposures in a Place of Worship have the greatest collapse potential

A

Exposures 2 and 4 (Bearing Walls)

And exposure side of the steeple or Bell Tower ( front of the building)

24
Q

When it is determined that the fire cannot be controlled with handlines, what strategy will be implemented next

A

Exterior fire attack

25
Q

True or false: TL’s should be placed near the front/center of a structure

A

False

Placed near the front of the structure in a “corner safe” area outside of the collapse danger zone

26
Q

When fire is located in the cellar of a Place of Worship, what size handline is used

A

1 3/4

Note: Mobility of operations are a prime consideration when fire is located in a cellar

27
Q

Name 3 places a fire may originate in the cellar area of a church

A
  1. Gas/oil fired boilers for heat or hot water
  2. Electrical service panel boxes
  3. Kitchen stoves used in daycare facilities
28
Q

For cellar fires, where should the 1st handline be stretched to

A

Entrance door that provides the quickest access to the cellar

29
Q

The use of a third line in a Place of Worship will be directed where

A

Directed by the IC

30
Q

Name 2 areas of a church where handlines will not be able to extinguish fire due to limited access

A

Attic or Bell Tower

Once fire reaches this area, firefighters will have to be withdrawn and an exterior operation employed

31
Q

True or false: The Rose window may provide adequate ventilation of the large vaulted spaces in churches

A

False. Rose window “May Not” provide adequate ventilation. Generally it is best to vent the window closest to the fire in conjunction with the hoseline advancement and fire extinguishment

32
Q

When does the first arriving ladder company assume responsibility for the entire church structure

A

Until second ladder company arrives

33
Q

Who is responsible to ensure that the cellar area is examined for fire

A

Second arriving ladder

34
Q

Name two different types of roof coverings mentioned in this bulletin that add a significant dead load to a Place of Worship

A

Slate and Terracotta Tile

35
Q

Where should a rear mount aerial ladder be placed at a church fire

A

Away from the immediate fire building.

Note: Make room for the TL

36
Q

The incident command post will be located where

A

Front of the fire building but outside the potential collapse zone

37
Q

The IC should consider transmitting an additional alarm during what occasion

A

Two handlines are anticipated or are in operation on the interior

38
Q

A properly positioned TL can cover a building with a frontage of how many feet

A

100

39
Q

When fire is located within the large open area of the Nave, the first priority is a TL stream located where

A

Into the Rose Window

Note: When fire is not visible within the large area but suspected to be within the concealed area of the attic or cockloft, water application into the ventilation opening is the priority

40
Q

What action can start minor fires in the surrounding areas of a Place of Worship

A

The force of updrafts

Note: This will send large pieces of burning material quite some distance

41
Q

At a cellar fire where will the 2nd hoseline be stretched to.

A

Charged outside of the fire building to back up 1st line.

Note: If not needed for back up then stretch to floor above