Lofts Flashcards

1
Q

Lofts can be what type of class construction (4 answers)

A

Class 1, 2, 3 or 6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which type of loft is considered to be the least common type

A

Mill (Heavy Timber)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which type of loft is considered to be the most common

A

Fireproof lofts

Note: Also the newest type

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The maximum height of older cast-iron lofts

A

7 to 8 stories

Note: These lofts were built between the 1840’s and 1870’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The frontage and depth of older cast-iron lofts

A

Frontage: 25 ft.
Depth: 90 ft.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The number of staircases found in older cast-iron lofts

A

Only 1

Note: Will be wooden stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The height of newer cast-iron lofts

A

8-12 stories

Note: Constructed from the 1880’s to 1901

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The width and depth of newer cast-iron lofts

A

Width: 50 feet
Depth: 90 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Larger irregularly (P shaped) newer cast-iron lofts will have lengths and depths of how much

A

Width: 100 feet
Depth: 200 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The height of mill lofts

A

4 to 6 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The type of stairways found in mill lofts

A

Fire towers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The height of fireproof lofts

A

10 to 15 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The width and depth of fireproof lofts

A

Width: 50 to 100 ft. or more
Depth: 75 to 200 feet
Note: Some can span an entire block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Name 2 ways fireproof lofts can be interconnected

A

By automatic fire doors or joined via exterior bridges (skywalks)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Fireproof lofts that are over 75’ in height may have how many fire towers

A

1 or more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

In fireproof lofts, the automatic sprinkler/standpipes are tied into what 2 water systems

A

City water system or roof gravity tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Vaulted sidewalks are supported by what 2 structural members

A

Wrought-iron I beams OR cast iron

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

If a loading dock is present in a loft, freight elevators may be found how far in from the front of the building

A

20 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Name a reason why freight elevators are not used initially at fire operations

A

Will be located close to rubbish removal areas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Aerials and portables should not be placed on what type of windows

A

Any window that serves the elevator shaft

Note: These windows are required to display a “SHAFTWAY” sign in front

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Utility shafts will terminate in what area of a loft

A

The roof level

Note: Can present severe vertical and horizontal fire extension problems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Name 5 types of fire escapes found in loft buildings

A
  1. Standard 2. Counter balance stairway/ladders 3. Vertical 4. Party wall balconies 5. Exterior screened stairway
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Straight run stairs made of wood and covered with wainscoting will also be covered with what

A

Tin

Note: Do not overlook this area during overhauling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Original hardwood finished flooring is from ____ to ___ of the building mill lofts

A

Front to rear

25
After (2) 2 1/2” lines are stretched up a stairway, name 3 other ways to get a 3rd line up to the fire floor
1. Alternate stairway 2. Exterior rope stretch 3. Fire escape
26
When will the 2nd hoseline be stretched to the floor above
Only when not needed on the fire floor
27
Outside streams will be used to extinguish what type of fire
Visible
28
Positioning of the hoseline with FF’s to the side of the entrance to fire area will be done when
Potential backdraft on intermediate floors when vertical vent is not possible
29
What type of floors exposed to fire can spall violently and possibly fail when struck by water
Segmented Arch Floors | Note: Use reach of the stream and do not operate the line directly overhead
30
Sprinkler systems may serve which floors
Cellar and sub-cellar | Note: May be Dry piping with fusible link sprinkler heads OR Perforated pipes
31
Non automatic sprinkler systems rely on what type of water source
FD water supply solely
32
True or false. In lofts where the sprinklers serve the upper floors, section valves may be found on individual floors/areas
True | These valves must be checked to ensure they are in the full open position
33
The number of interior stairs typically found in cast iron loft buildings
1
34
Who will ensure the sprinkler system is supplied
3rd due engine
35
True or false. At upper floor fires where 2 lines have already been stretched, the High Rise Nozzle can be a consideration as the 3rd line
True
36
Cast iron lofts may have up to 4 doorways fronting the street. Name the 4 types of doors
1. Freight elevator 2. Residential elevator vestibule 3. Commercial entrance 4. Interior stairway entrance
37
When will engine companies operate in accordance with FFP Class A FP MD’s
Fireproof Loft Buildings
38
How will elevators that are very old with limited load capacities and open cage cabs be operated
Manual mode requiring an operator | Note: These elevators will not have Fireman Service
39
Name 2 tool requirements for lofts that have large open floor areas
Search ropes and TIC’s
40
In cast iron and mill loft buildings where fire is in the cellar/ sub cellar, what will the 2nd ladder do if the 1st ladder cannot make access down interior stairs
Gain access to cellar area via alt. route (adjoining building)
41
In cast iron and mill loft buildings where fire is in the cellar/ sub cellar, ladder chauffeurs will be positioned where
Front of the building | Note: This member will be available to position or reposition ladders as needed
42
In cast-iron and mill loft buildings, name 3 ways the roof man gets to the roof
1. Adjoining building 2. Aerial/ TL 3. Fire escape
43
When fire is located in the lower floors of cast iron and mill loft buildings, where will the 1st OV be positioned
Rear of the building to coordinate vent | Note: Only exception is to assist LCC with a life hazard in front of the building
44
When will ladder companies operate as per FFP Class A FP MD’s
Fireproof Loft buildings
45
Where does the 1st due BC establish the command post
Front of the fire building
46
If structural stability of a gravity tank is questionable what can be done
Drain the contents of the tank and divert the water off the roof into a drain pipe OR open a standpipe outlet on a lower floor
47
LCS’s should avoid striking what part of a loft building
Columns | Note: Floor collapse can occur by the failure of a single column
48
When fire is located at upper floors of cast iron and mill loft buildings, who is responsible to bring the saw to the roof
2nd due roof
49
True or false. When properly cast, structural members of cast-iron will withstand a great deal of thermal stress
True
50
What will happen if an improperly cast column is cooled by a hoseline
Will contract disproportionately leading to potential failure
51
At 1100 degrees cast-iron loses ____ % of its original strength
58% | Note: The strength lost is cumulative and never regained
52
Which type of columns will elongate or extend when heated
Iron fibers (just like steel)
53
Which type of columns will crack when heated
Cast-iron
54
In a Cast Iron / Mill Loft Building and fire is located in the cellar/sub cellar, which engine will supply the sprinkler
2nd due | Note: But only if 1st engine has not done so
55
In a Cast Iron / Mill Loft Building and fire is located on a lower floor, which engine will ensure the sprinkler is supplied
3rd due
57
Steel tension cable rods can fail at _____ degrees
800 | Note: These will be found in Mill Lofts
58
Iron window shutters will generally be installed on which sides of a loft building
Rear and Side walls
59
Iron window shutters are mandated to be installed in buildings less that ___ ft. from another building
30 ft. | Note: Or less than 50 feet vertically from the roof of an adjoining building