TX Final Flashcards
Roof inspections always require _____ and _____.
Walking on the roof
Identification of the roof covering material
During the inspection of a fireplace, inspectors look for presence and adequacy of _____ _____ and presence and condition of _____ _____, _____ _____, and _____ _____.
Presence adequacy of non-combustible hearth extension
Presence and condition of coping or crown flashing, spark arrestor, and rain cap
Hazardous conditions related to a drain line serving a temperature-and-pressure relief valve installed in a water heater includes drain line with _____, _____, and _____.
a threaded discharge end
sloped to prevent positive gravity drain
3/8 inch diameter pipe
One item that is not important to the inspection of a gas fired water heater is:
Gfci
How many inspections must a professional inspector have completed before he can sponsor another inspector?
200
You are performing an inspection and observe a duplex receptacle outlet being used under the kitchen sink. What would you expect to observe in the panel/box?
Two manufactured breakers linked together
Top of the tub to the bottom sash of a window measures 63 inches. There is no safety glazing etching. Is this deficient?
No, it is not a hazardous location
Fireblocking is _____ in open, concealed wood-framed spaces.
Required
System grounding conductors Are connected to _____ or _____.
a metal grounding rod or water supply line.
For proper combustion, a gas fired forced air furnace requires adequate availability of _____ and _____ combustion air.
primary
secondary
The purpose of a draft diverter at the flue collar of a natural draft gas fired furnace is to prevent the _____ into the burner compartment and allow the _____ into the flue.
Downward flow of air
Free flow of draft air
The flue serving a gas fired furnace with natural draft venting must Exhaust at a point _____ or more vertical feet above the ____ ____.
5
flue collar
Automatic motorized garage door operators are required to ____ ____ automatically if there is an obstruction in the path of a closing door.
reverse direction
All of the following must be joined in a unified electrical bonding with #8 AWG copper wire, except:
electrical metallic tubing secured to a building less than 5 feet from a pool’s edge.
Landscape irrigation (sprinkler) systems backflow preventers must be located _____ than the ____ spray head in the system.
higher
Lowest