National 4 Flashcards
Poured concrete retaining walls should have _____ between the wall and the soil, to prevent _____.
gravel
rotation
Blocked _____ can have adverse effects on foundations and basement walls.
gutters
Foundation settling of a concrete basement wall can show symptoms such as _____.
efflorescence
Movement joints in brick veneer are required at points where support is derived from _____ _____ _____.
different structural components
Adhered masonry veneer is installed in the same manner as _____.
Stucco
The most appropriate fastener material for a slate shingle roof covering is _____.
Copper nails
The water resistive barrier installed under three coat stucco should be at least _____.
Two layers of 60 min grade a paper
safety glazing is not required at the _____.
Top of landing
A collar tie would most likely be found in _____.
The upper part of attic
The MAXIMUM allowed depth notch in a twelve-foot-long 2x10 floor joist located five feet from the joist end is _____.
0 inches
You see a ceramic tile floor with numerous cracks running through the grout and the tiles.
The floor system is constructed by 2x10 floor joists. Which is the most likely cause of this condition?
The floor joist span is too long.
Ceiling joist that meet at a load bearing wall should lap each other at least _____.
3”
Which material is most appropriate for fastening slate shingles?
Copper
The grounding electrode system of a house provides an _____.
alternate return path for electricity
Metal touching an energized conductor is most likely to cause _____.
Arc flash
A subpanel in a detached building has melted insulation on a neutral conductor. What is the most likely cause of this condition?
The neutral conductor is loose at the terminal bar
Service entrance conductors in sheathing should be how far from a deck _____ ft.
0
A house is serviced by 2-200-amp panel box. What is the amperage for this house?
Unable to determine
Common defect with Edison base fuses?
Fuses are susceptible to overfusing.
1950’s home with 3 prong receptacles show as grounded. What is the issue?
The ground is connected to the grounded connections.
Loose receptacles could lead to a _____ _____.
Fire hazard
A 240-volt dryer circuit is a _____.
multi-wire branch circuit
The effect of high humidity on an air conditioning system will be _____.
decrease in the sensible load
What is most likely to cause the greatest reduction of air flow in a flexible air duct?
A 90 degree bend in the duct.
What is the most likely result of insufficient air flow across the evaporator coil?
Ice forms on the evaporator coil
Which is not a factor when determining cooling load calculations?
Roof coverings