National Study Guide Flashcards

1
Q

Copper tube boilers have ____ heat transfer and ____ life span compared to cast iron boilers.

A

Better
Shorter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In an open system, the expansion tank is located ____ the ____ level radiator.

A

above the highest

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Standard 3 light receptacle testers are not always reliable because different manufacturers have ____ ____ ____.

A

different light patterns

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A downspout should terminate ____ grade ____ feet from the house.

A

Above grade 6’ from the house

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

You can check for flooring and subfloor thickness by removing a ____ ____ ____.

A

supply air register

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Should service entrance wire be run inside a building before entering the service box?

A

No, and if no other option then as short as possible.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Steam heat is a type of ____ heating system.

A

Hydraulic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Serious cracks tend to be ____ in orientation.

A

Horizontal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Do faucets require isolating valves?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Heat pumps may sometimes have ___ expansion devices.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Vented decorative appliances shall be installed according to _____, conform with ANZI _____, and be supplied with both ____ and ____ ____.

A

Manufacturers instructions
Z21.50
Combustion and circulating air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Home inspectors must disclose any interests in a ____ that may affect the ____.

A

Business
Client

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Inspection reports should focus on the ____ that people should ____.

A

actions
take

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The final decision to enter the crawl space is made by the _____ when scheduling.

A

Client

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

High efficiency furnaces installed in old ductwork have ____ ____ ____.

A

Shorter life spans

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Radiant heating systems are usually located in the _____.

A

Ceiling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

A cracked heat exchanger or rusted burners cause accumulation of CO gas, which could result in _____.

A

spillage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

A chimney should extend at least ___ ft beyond the point at which it penetrates the roof.

A

3’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

____ pipe may not be used for potable water.

A

DWV -drain waste vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Is there a limitation on the number of receptacles that can be placed on a lighting circuit?

A

No

21
Q

Where a masonry wall meets a roof surface, ____ ____ is required to prevent water penetration.

A

Counter flashing

22
Q

Backflow prevention devices for a lawn irrigation system typically lasts about ____ years.

A

12

23
Q

NM cable sheathing may be repaired with ____ ____.

A

Electrical tape

24
Q

The minimum clearance between a masonry chimney and combustible material is ___ inches.

A

2”

25
Q

A steel sink will typically rust out at the ____ ____.

A

Overflow channel

26
Q

A masonry chimney with 2 high and 2 low air grill inserts is evidence of a _____.

A

Heatilator

27
Q

The function of a draft hood on a gas water heater is to ____ air to the ____ system to maintain chimney ____.

A

add
venting
draft

28
Q

The flue serving a gas fired water heater must be the ____ wall type, must terminate at least ___ ft above the roof or any surface within ___ ft of the termination, and requires a noncombustible ____ at any ceiling or wall penetration.

A

double
2’
8’
thimble

29
Q

A ____ ____ flex connector may not be used as a gas connector for a pool heater

A

bare brass

30
Q

Joist ____ has little effect on deflection.

A

width

31
Q

A lack of ____ ____ can cause water hammer.

A

air chambers

32
Q

Switching from natural gas to propane requires installing a new ____, or the flame will be too ____.

A

orifice
high

33
Q

Low pressure boiler pipes carry pressures at or below ____ PSI.

A

15

34
Q

Foundation drains collect water as it passes ____ through the ____.

A

laterally
slope

35
Q

The minimum slope roof in which asphalt shingles may be used is _____.

A

2/12

36
Q

Squash blocks should be used on I joists at ____ ____ and ____ ____ walls with support ____ below.

A

bearing ends
load bearing
girders

37
Q

Electrical service wires require a minimum of ____ ‘ clearance above walking surface and ____ ‘ above a roadway.

A

10’
18’

38
Q

A higher temperature differential could suggest a ____ ____ ____.

A

dirty air filter

39
Q

A residential driveway requires at least ___ ft of clearance for electrical service wires.

A

12’

40
Q

A ____ union is used to separate differing metals to prevent ____ action and ultimately _____.

A

dielectric
galvanic
corrosion

41
Q

The minimum clearance between wood stove single wall vent connector and combustibles is ____ inches.

A

18”

42
Q

Capillary tubes are part of a _____ _____.

A

Evaporator coil

43
Q

Minimum clearance between masonry chimney and combustibles is ___ inches.

A

2”

44
Q

An ____ meter can be used to confirm bonding of appliances.

A

Ohm

45
Q

Service panels must open at least ___ degrees.

A

90

46
Q

A residential refrigeration system requires regular cleaning of the ____ ____.

A

Condenser coil

47
Q

Windows requires safety glass if the bottom edge is within ____ of the floor.

A

18”

48
Q

Crawl spaces with a vapor retarder require 1 sq ft of ventilation area per _____ sq ft of crawl space.

A

1500 sq ft