TSO's Flashcards
1
Q
2A F/O Suction and Recirc Valve?
A
- Does not indicate closed on PACC
- Verify closed position locally.
2
Q
NR1 MRG Attached LOSP Hose?
A
- Hose is bulging and sagging.
- Limited to 81 SRPM on STBD shaft.
3
Q
NR3, NR5, NR7 Hydraulic Stations?
A
- Indicates Open/Shut position when stations are closed.
- Verify position locally.
4
Q
1SG Generator Breaker?
A
- When shifting from Shore Power to Ship’s Power breaker opens and closes during remote operation.
- 1 GTG shall not be used to operate in parallel with shore power.
5
Q
RO Demineralizer Rejects Flow Meter?
A
- During operation water leaks out of rejects flow meter sight flow glass.
- During operation open bypass valve and secure inlet and outlet valves to sight flow glass.
6
Q
Reefer Deck Parasense Monitor?
A
- Displays fault status.
- IEM/ASM will check receiver level every 2 hours. If level decreases report to EDO/EOOW who will contact A-Gang to conduct leak test.
7
Q
FM-V-3-323-2?
FM-V-3-219-2?
FM-V-1-105-2?
A
- Valves do not display closed indication in CCS.
- Verify position locally.
8
Q
NR1 and NR2 L/O Purifiers?
A
COMNAVSURFOR Message
- Venting L/O purifiers every hour is not sufficient to prevent deterioration.
- Vent every 30 minutes while in use.
9
Q
RHIB?
A
- Damage to throttle and steering column.
- Boat Deck POIC and Boat Officer verify all hoist and sling lines are clear of obstructions before placing tension on boat hoisting hook.
10
Q
Computer Assisted Rudder Roll Stabilizer?
A
- During operation displays critical faults.
- OOD will not authorize use of Computer Assisted Rudder Roll Stabilizer.
11
Q
NR3 SG Generator Breaker?
A
- Breaker will not close remotely.
- Charge breaker locally prior to being closed by EPCC.